EasyManua.ls Logo

Intermatic SS7 SERIES - Other Installations; Installations including a Dimmer; Special applications; Troubleshooting Guide

Intermatic SS7 SERIES
2 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LIMITED ONE YEAR WARRANTY
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of
charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or
abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance
with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/
or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER
EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE
WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY
NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage
prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7000
http://www.intermatic.com Please be sure to wrap the product securely to avoid shipping damage.
Wiring diagram, 3 switch installation:
For3ormoreswitchoperation,ANADDITIONALWIREMUSTBEADDEDbetweentheloadandthetimer.
Thejumperwireisnotrequiredfortheseapplications.
4 or more switch installation:
For4ormoreswitchinstallationsusethepreceding3switchinstallationdiagramandwire4-wayswitches
betweenthetwo3-wayswitches.
LINE
BLACK
TIMER
BLUE
LOAD
NEUTRAL
TWO3-WAYSWITCHES
Forexisting3switchinstallationsreplaceone3-wayswitchwiththetimerandreplacethe4-wayswitchwitha
3-wayswitch.
RED
ADDITIONALWIRE
Other Installations
MULTISWITCH APPLICATIONS USING THE ELECTRONIC TIMER ARE WIRED DIFFERENTLY THAN
WHEN USING CONVENTIONAL TOGGLE SWITCHES. READ THE FOLLOWING INSTRUCTIONS
CAREFULLY.
Special applications
Becauseofit’sunique“hard contact” switchfeature,yourtimermaybeused for applicationsnotpreviously
possibleforelectronicwalltimers,suchasusewithdimmers,usewithoututilitypower,useoncircuitsother
than120volts,controllingrelaysorcontactors,ortocontrolDCvoltage(forexampleinrecreationalvehicles).
Seeinstructionsabovefordimmerapplications.ForDCandhighvoltageapplicationspleasenotethereduced
loadratingsonproductlabel.Consultfactoryforapplicationdetails.
Multipletimersmaybemountedinadjacentjunctionboxslots.
Noderatingisrequiredformultipletimers.
Wiring diagram, 2 switch installation (3-way):
NOTE:Fornewconstructionortoreplaceadimmerswitch,alightedswitch,ora3-wayswitchwithoutscrew
terminals,asinglepoleswitchcanbeusedattheremotelocation,asshownbelow.
LINE
BLACK
TIMER
BLUE
RED
JUMPER
LOAD
NEUTRAL
3-WAYSWITCH
COMMON
Installations including a Dimmer:
•Theloadsizeandtypemustnotexceedtheratingofthedimmer.
(Typically600watts,120VAC,60Hz,incandescentlampsonly.)
•Ifthedimmerisplacedinit’s‘OFF’position,thetimercannotoperatethelights.
•Ifthedimmerissettoolow,thelightsmaynotturnbackonundertimercontrol.Ifnecessary,usea
premiumqualitydimmerthatcanbeturnedonatverylowsettings.
LINE
BLACK
TIMER
BLUE
RED
DIMMER
LIGHT
NEUTRAL
(Capped,NotConnected)
Multi-switch installation using a dimmer :
A3-waydimmershouldnotbeused.Ifamulti-switchinstallationisrequired,usethefollowingdiagram.
LINE
BLACK
TIMER
BLUE
RED
DIMMER
LIGHT
NEUTRAL
REMOTESWITCH
Note:THEREMOTESWITCH(ES)MAYNOTFUNCTIONRELIABLYWHENTHEACCUMULATEDWIRE
LENGTHTOTHEREMOTESWITCH(ES)EXCEEDS30FEETORIFTHEWIRINGTOTHEREMOTE
SWITCH(ES)ISBURIEDUNDERGROUND.Consultfactoryfordetails.
Note:Usedremoteswitchesfromapreviousconventionalinstallationmaynotfunctionreliablywithan
electronictimer.Tryabrandnewremoteswitchiffunctionisintermittent.
158SS12527
TROUBLESHOOTING GUIDE
Timer does not operate, display is dim, blank or unreadable,
displayshowsnonsenseor‘lobAt’,ortimeroperateserratically.
Batteryiswornout,missingorisinstalledbackwards,ortimer
wasoperatedwhilebatterywasremoved.
Install a fresh AAA size alkaline battery in the direction indi-
cated.PressRESETbutton,thenreprogramtimer.
Timerdoesnotswitchbutdisplayisnormal.
TimernotinAUTO,AUTORAND(om),orMAN(ual)mode. UseMODEpushbuttontoselectthedesiredoperatingmode.
UseMODEpushbuttontoselectAUTOorAUTORANDTimernotinAUTOorAUTORAND(om)mode.Timerworksmanuallybutdoesnotfollowscheduledprogram.
Timerwon’tentertheAUTOorAUTORANDmodeswhen
MODEbuttonispushed.
Timeofdayand/orswitchingtimesarenotprogrammed. Make sure time ofdayandatleastonescheduledactivityare
programmed.
Review/ReviseALL6ON/OFFswitchingtimepairsbyrepeat-
edlypushingtheON/OFF/EVENTbuttonwhileinPGMmode.
Programmedschedule(s)areincorrect.
UseMODEpushbuttontoselectAUTOmode.TimerisinAUTORAND(om)mode(Variesswitchingtimesup
to+/-15minutes).
Timer switches at incorrect times or skips some switching
times.
Afterenteringyourschedulesorthetime,thenreturningtothe
AUTOmodes,pushtheON/OFF/EVENTbuttontochangethe
loadstateifnecessary.
Timerdoesnot“catchup”totheprogrammedloadstate.The
loadwill remainin it’sstate priorto enteringthe PGMmode.
Thetimerwillbeginfollowingthescheduledprogramatthenext
contraryON/OFFtime.
Loadstatedoesn’tmatchprogrammedstateimmediatelyafter
programmingthetimeorschedule.
Displayshows‘noOp’. Mechanismisinoperative.
Iftimeris inavery coldenvironment,tryagainwhenwarmer.
Ifnot,andifthebatteryisgood,thetimershouldbereplaced.
Pushinbatterycoveruntilyouhear aclick. Pushresetbutton
tocleardisplayandreprogramtheunit.ReplacedeviceifNoOp
willnotclearfromdisplay.
Makesuretimerdisplayshows‘ON’thencheckdimmeropera-
tionatfullbrightnesssetting.Iftimercontrolisrequiredatvery
lowbrightnesssettings,useapremiumqualitydimmerthatcan
beturnedonwhensetlow.
Dimmeristurnedofforissettoolowtoturnbackonorthe
bulbisburnedout.
Timeroperates,butlightdoesn’tcomeon indimmer applica-
tions.
Loadonly operates whenthe remote (3-way)switch is inone
positionortimerignorestheremoteswitch.
Remoteswitchiswiredincorrectly.
Recheck wiring, especially for the jumper, per “Installation
Instructions - 3-Way Switch” and“Other Installations”.
Eliminate condition, replace the buried cable, do without the
remoteswitch,orconsultfactoryforotheroptions.
Replaceremoteswitch.
Excessivelengthofwire(greaterthan30feet)orburiedwiring
totheremoteswitch.
Remoteswitchisdefectiveorwornout.
Timer ignores remote (3-way) switch even though it is wired
correctly.
REMEDYPOSSIBLE CAUSESYMPTOM
Batteryholderisdifficulttosnapinplace Batterynotseatedinholder,holdermisaligned,orcontacttabs
ofholderarebent.
Lineuptabsonbottomofholderwithnotchesintimerhousing
whenpushingin.Straightenbentcontacttabs.
Loadturnsoffimmediatelyafterbeingturnedon. Remoteswitchortimer wired incorrectly, excessive length of
wire (greater than 30’) or buried wiring to remote switch, or
defectivetimer.
Iftheproblempersistswiththeredwiredisconnectedorwith
a ‘remote’ switch temporarily connected right at the timer,
replacethedefectivetimer,otherwisetrytheaboveremedies.
Wiring diagram, 2 switch installation (3-way) using a single pole remote switch:
LINE
BLACK
TIMER
BLUE
RED
SINGLEPOLESWITCH
LOAD
NEUTRAL