21
8 - USE OF ROTOTEK OR MULTIREG 99
9 - PRECAUTIONS AGAINST FREEZING AND INSTRUCTIONS FOR STORAGE
If the machine is stored where temperatures fall below the freezing level, it is advisable to suck
antifreeze (similar to that used for automobiles) into the pump before storage. In any case keep
the machine in a warm r oom for a couple of minutes befor e use.
OFF
2
1
3
HL
HL
4
5
HL
HL
A
B
Pressure selection must be carried out with closed pistol (1)
A - selection of the pr essure
• High pressure (2)
• Low pressure (3)
B - selection of the jet
straight pin jet (4)
fan jet (5)
10 - MAINTENANCE
Maintenance and repairs should always be performed by trained and authorised personnel.
Before carrying out any cleaning, maintenance and/or parts r eplacement, disconnect the
machine from the power mains, removing the plug from the power outlet.
• Proper maintenance favours a longer duration of operation and impr oved performance.
• Periodically check the conditions of the washer, pressurised parts (pipe, fittings, lance) and
the electrical cable (see "General war nings for use").
Check for any water or oil leaks and/or malfunctions.
If necessary, replace affected parts.
The list of specific machine components and cir cuit diagrams are contained in the booklet
"SPARE PARTS NOMENCLATURE".
Contact Interpump Group customer service in the event of any doubts.