IMPORTANT
Sanifount - Sensor Operated
Trouble - Shooting Guide
INTERSAN MANUFACTURING COMPANY
1748 W. Fillmore St. - Phoenix, Arizona 85007 - Tel 602.254.3101 - Fax 602.254.1776 - www.IntersanUS.com
NOTE: THIS INFORMATION IS SUBJECT TO CHANGE WITHOUT FORMAL NOTICE REV1.2
- 1 -
Always reset the Microprocessor after
each intervention (reset button mounted
in the lid). After 35 seconds each station
should be operational.
PROBLEM 1: UNIT CONTINUOUSLY BEEPS WHEN ACTIVATED
Replace Battery-Pack
Step 1
Remove the stainless steel lid from the
distribution head by inserting the supplied
key and turning the lock counterclockwise.
The cover should move forward and gently
lift the front of the lid and remove.
Step 2
Disconnect the battery by depressing the
battery terminal lock and gently pulling the
two halves apart.
Step 3
a. Test the battery for the proper 10.8
voltage.
b. Look for possible loose leads or
connections to cause low voltage.
c. Replace or reinstall the battery. Reverse
steps 1 & 2. Push the reset button and
wait 35 seconds.