Error Code E94
This code indicates very low water temperature which could be due to frigid water or a problem with the
20-40 C water temperature sensors. Please follow the logic diagram and instructions as below:
Begin the test by installing the spa control base and panel to a tub filled with water to the recommended
level. Make sure that the water inside the tub is not colder than 4. Turn on the spa control base.
No
Display E94
Yes
1. Add warn water if water temp. <4
2. Replace 20-40 temperature sensor
3. Or replace a PCB
Go Back to Next Step
END
Run heat 5 min.,
E94?