TROUBLESHOOTING (continued)
LED PANEL
CODE
PROBLEM SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).
E81
Transmission signal failure.
Reset the GFCI/RCD, restart all over again.
Place the control panel within 5 m (16 ft) of the control base unit.
Press and hold POWER button for 5 seconds to turn off and
charge the panel again.
If problem persists, contact Intex Service Center.
E90
No water ow.
Turn off and unplug the control unit.
Ensure the outlet cover grid is clean and free from obstructions.
Clean or replace the cartridge, see Maintenance and Storage section.
Ensure the in/outlet connections on the spa tub and lter pump are
not blocked.
Keep the spa water properly sanitized to ensure a clean and
unclogged lter cartridge.
Turn off and unplug the control unit. Plug the GFCI/RCD and restart
all over again.
If problem persists, contact Intex Service Center.
E91
Dirt or scale on titanium plates.
Low salt level / No salt.
Electrolytic cell cord is loose.
Possible electrolytic cell failure.
Remove the electrolytic cell for inspection. Clean it if necessary.
See “Maintenance”.
Add salt. See “Salt Level Information”.
Ensure that the cell cord is plugged fi rmly into the cell receptacle.
Contact Intex Service Center. Replace the cell if needed.
E92
High salt level.
Partially drain the pool and refi ll it with fresh water. See “Salt Level
Information”.
If problem persists, contact Intex Service Center.
E94
Water temperature too low. • If the ambient temperature is below 0°C (32°F), we recommend not
to use the spa.
Turn off and unplug the control unit, add some warm water to raise
the spa water temperature above 1°C (34°F), then press the
button to heat up the water to the desired temperature.
If problem persists, contact Intex Service Center.
E95
Water temperature too high.
Turn off and unplug the control unit. When the water has cooled
down, plug the GFCI/RCD and restart all over again.
Turn the heater off , then press the fi lter and bubble buttons to
lower the water temperature.
If problem persists, contact Intex Service Center.
E96
System Error.
Turn off and unplug the control unit. Plug the GFCI/RCD and
restart all over again.
If problem persists, contact Intex Service Center.
E97
Dry-fi re Protection.
Contact Intex Service Center.
E99
Water temperature sensor
broken.
Contact Intex Service Center.
END
After 72 hours of continuous
heating operation, the pump will
hibernate automatically. The
rapid heating function is disabled.
Press the
button to re-active the lter pump.
NO LED
DISPLAY
LED display is off
Charging Failed
Control Panel failure.
Press any button to reactivate the control panel.
Reset the GFCI/RCD, restart all over again and charge the control
panel again.
Make sure the surface between the back of the control panel and
the control base charging dock is clean, dry and free of obstruction.
If problem persists, contact Intex Service Center.