Do you have a question about the Intramech SWC-15-V-ECM and is the answer not in the manual?
Provides general specifications and performance data for SWC-V-EC series.
Details coil specifications for 2-pipe systems, including fin dimensions and tube diameter.
Presents cooling capacity data for 2-pipe systems across various conditions.
Presents heating capacity data for 2-pipe systems across various conditions.
Provides dimensions and a differential pressure chart for the 2-way valve body.
Details the process of installing the high-wall fan coil unit, including location selection.
Provides detailed dimensions for mounting plates for different SWC models.
Instructions for securely mounting the unit's plate onto the wall.
Guidance on drilling the condensate drainage hole with correct dimensions and slope.
Steps for hooking the indoor unit onto the mounting plate and securing it.
Proper installation of drain hoses for free drainage and avoiding water damage.
Covers unit maintenance tasks and preparation steps before operation.
Procedure for purging air from the coil and water system.
Information on accessing and making wiring connections within the control box.
Illustrates pre-assembly and complete assembly of pipe connections with a valve.
Details the SK-NCSWC-001 controller, its functions, and configurations.
Provides the wiring diagram for the SK-NCSWC-001 FCU controller.
Explains DIP switch settings for unit configuration and operation modes.
Details control logic for cooling, heating, and fan modes in 2-pipe systems.
Control logic for 2-pipe systems without thermoelectric valve.
Details control logic for cooling, heating, and fan modes in 4-pipe systems.
Explains the auto fan speed regulation based on room temperature in cool/heat modes.
Describes louver angle and swing settings for remote handset and wired wall pad.
Details buzzer response for master and slave units upon receiving commands.
Explains how operation parameters are retained after power loss or system failure.
Guides on using the unit's on-unit control panel for mode selection and settings.
Lists LED blink patterns, reasons for errors, and remedies for unit faults.
Describes master unit LED indications for slave unit failures and remedies.
Explains the master-slave network structure and unit roles.
Details the steps and components for setting up a master-slave network connection.
Instructions for setting the master unit using a remote control handset.
Instructions for setting the master unit using a wired wall pad.
Explains Global Control and Addressable communication methods for master-slave networks.
Provides a wiring diagram for master-slave network connections between units.
Lists input/output definitions for the SK-NCSWC-002 controller.
Presents the wiring diagram for the SK-NCSWC-002 FCU controller.
Details DIP switch settings for modulating signal input and fan motor configuration.
Explains power on, swing/louver, and signal input logic for the controller.
Shows LED status for unit on and unit in standby modes.
Lists LED blink patterns, reasons, and remedies for sensor and motor failures.
Lists supported Modbus function codes for communication.
Defines Modbus error codes and their meanings for troubleshooting.
Details the functions and operation of the remote control handset.
Describes the wired wall pad display and its control functions.
Explains the layout and indicators on the wired wall pad display.
Provides instructions on operating the wired wall pad for various functions.
Steps for setting the EC unit RPM using DIP switches and the wired wall pad.