32
room temperature from the remote controller
and the setting temperature.
3) The PCB will take action to the mode
change information from remote controller
signal, but it will not affected by the setting
temperature.
4) When the unit is running with follow me
function, if the PCB doesn’t receive any signal
from remote controller for 7 minutes or pressing
FOLLOW ME button again, the follow me
function will be turned off automatically, and the
temperature will control the unit according to
the room temperature detected from its own
room temperature sensor and setting
temperature.
7.4.14 Silence operation(optional)
Press the “silence” button on remote controller
to initiate SILENCE function. When the Silence
function is activated, the compressor running
frequency will keep lower than F2 and the
indoor unit will bring faint breeze, which will
reduce the noise to the lowest level and create
a quiet and comfortable room for you.