PAGE 10
OBLICA | PHAROS INSTALLATION AND USER MANUAL
5. TESTING
TEST REPORT NO HCMG/15/041
TESTING LABORATORY: HRL Technology
MANUFACTURER: Invicta
MODEL: Pharos fireplace
WORK REQUESTED: Assessment of appliance to AS/NZS 4012:2014
for determination of Power Output and Efficiency
and AS/NZS 4013:2014 for Flue Gas Emission
using hardwood fuel.
ISSUE DATE: 23/07/2015
INVESTIGATING OFFICER: Steve Marland
RESULTS: The Pharos solid fuel burning appliance produced an
appliance particulate emissions factor of 1.2g/kg and an
average efficiency of 60% for all burn rates, using
hardwood that complies to AS/NZS 4014.1, when tested
according to joint AS/NZS 4012, AS/NZS 4013 (2014).
CONCLUSION: The Pharos solid fuel burning appliance complies with the
requirement of a combined efficiency of not less than 55%
and a particulate emissions factor of not greater than
2.5g/kg of hardwood that complies to AS/NZS 4014.1 in
AS/NZS 4013 (2014).