1. Inspect the equipment and accessories for mechanical and functional damage.
2. Inspect the safety relevant labels for legibility.
3. Inspect the fuse to verify compliance with rated current and breaking
characteristics.
4. Verify that the device functions properly as described in the instructions for use.
5. Verify that the current/voltage sensors functions properly.
6. Verify software or firmware that performs safety critical application functions
properly.
7. Check earth connection, retightening of terminals
8. Check the following safety parameters which are factory set and fixed per IEC
62116:2008 and IEC 61727:2004, this trip point is factory set and fixed, user cannot
change this parameter.
Exceeding this limit will trigger de-energized-to-trip system and alarm within time as
specified in the following tables.
WARNING!
The device is not provided with ground-fault
detector/interrupter unit.