Goodrive300 Series VFD    Basic operation instruction 
150 
Detailed instruction of parameters 
0: Start-up directly   
1: Start-up after DC braking 
2: Start-up after rotation speed tracking 1 
Starting frequency of 
direct start 
Retention time of the 
starting frequency 
The braking current before 
starting 
The braking time before 
starting 
0: Linear type 
1: Reserved 
0: Decelerate to stop   
1: Coast to stop 
Starting frequency of DC 
braking   
0.00Hz–P00.03 (Max. output frequency) 
Waiting time of DC 
braking 
Dead time of FWD/REV 
rotation 
Shifting between 
FWD/REV rotation 
Set the threshold point of the VFD: 
0: Switch after 0 frequency 
1: Switch after the starting frequency   
2:  Switch  after  the  speed  reached 
P01.15 and delay of P01.24. 
Detection of stopping 
speed 
0:  Speed  setting  (the  only  detection 
method in SVPWM mode) 
1: Speed detecting value 
Terminal 
running protection when 
powering on 
0:  The  terminal  running  command  is 
invalid when powering on   
1:  The  terminal  running  command  is