Do you have a question about the INVT Goodrive20-EU Series and is the answer not in the manual?
Enclosure Rating | IP20 |
---|---|
Control Mode | V/F |
Overload Capacity | 150% for 60s, 180% for 3s |
Braking | Built-in braking unit (0.4kW to 15kW), external braking resistor can be connected |
Communication | Modbus-RTU |
Protection | Overcurrent, Overvoltage, Undervoltage, Overheating, Short Circuit |
Ambient Temperature | -10°C to +40°C |
Storage Temperature | -20°C to +60°C |
Humidity | 5%~95%, no condensation |
Altitude | Below 1000m, derating if altitude exceeds 1000m |
Defines safety terms, displays warning symbols, and provides general safety guidelines for VFD operation.
Covers safe delivery, installation, commissioning, maintenance, and disposal of VFDs.
Details unpacking, pre-application checks, environment confirmation, and basic commissioning.
Includes safety standards, decommissioning, specifications, nameplate, model code, and structure diagrams.
Specifies installation environment, direction, and modes for VFDs.
Details main and control circuit wiring, terminal connections, and I/O signal diagrams.
Covers STO function overview, logic, and layout protection measures like short-circuit protection.
Introduces keypad types, display zones, and parameter editing functions.
Covers modifying function codes, setting passwords, and viewing VFD status.
Lists parameter groups from P00 to P17, covering basic functions, motor parameters, control modes, and communication.
Outlines routine maintenance for ambient environment, circuits, fans, capacitors, and cables.
Lists fault codes, possible causes, solutions, and other operational states for VFDs.
Explains Modbus protocol, RS485 wiring, and communication modes (RTU/ASCII).
Details RTU/ASCII command codes, data formats, address definitions, and common communication faults.
Provides practical examples of reading and writing commands using Modbus protocol.
Lists common communication faults and their possible causes and solutions.
Covers derating due to temperature/altitude and EMC requirements for VFD categories.
Details CE mark requirements and compliance with European EMC directives.
Shows dimensions for external keypads, installation brackets, and VFD unit mounting.
Covers wiring, power supply, cables, breakers, reactors, filters, and braking resistors.
Guides on selecting and installing C3/C2 filters and braking resistors based on model and usage.
Lists power loss percentages and IE class for various VFD models.
Provides contact info for inquiries, feedback, and links to online documents.