EasyManua.ls Logo

IONFILTER Columbia Soda Upper - Maintenance Schedule; How to Empty the Carbonator

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instructions Manual
EN
• The inlet manual valve must be closed. Plug the system
to the power supply.
• Open the inlet valve of the equipment allowing the
sanitizing product to be pushed into it. Keep the inlet
valve in that position and fill a glass of water of each
type (in function of the model), in order to fill the entire
hydraulic circuit with the sanitizing solution.
• Close the inlet valve (5) and let the sanitizing solution
settle inside the equipment for 20 minutes. Meanwhile
sanitize the dispensing nozzles using sanitizing spray and
cotton swabs (6).
• Relieve the pressure of the circuit by opening the pull
handle tap. Empty the dosage housing. Before opening
this housing, make sure you have a receptacle in place
where you can empty it since it might be full of water.
Remove the complementary elements used for sanita-
tion and reconnect the feed tube to the inlet (In) of the
equipment.
• Open the inlet valve and extract 2 litres of water for
each dispenser in order to rinse the sanitizing solution
off the circuit.
• Use the sanitizing product detection strips to check
that the equipment is properly rinsed; empty as many
times as necessary in case of detecting sanitizing pro-
duct residues.
4
6
5
Close
9. MAINTENANCE
The following table shows how often maintenance ope-
rations must be performed.
TYPE OF OPERATION FREQUENCY
Cleaning of the outlet nozzle Weekly
Ordinary sanitation Half-yearly
9.1. HOW TO EMPTY THE CARBONATOR
CSH-NFG
• Close the inlet valve of the installation. Close the CO2
regulating knob. Press the button to dispense filtered
water at room temperature and cold water until no
more water comes out of the equipment. Repeat the
procedure with the carbonated water button; the equi-
pment will dispense approximately 1 l of water.
• During the process, ignore the operation of the pump.
Press the carbonated water button again to extract the
remaining gas. The emptying procedure will be comple-
te.

Table of Contents

Related product manuals