Manual técnico
RECOMMENDED MAINTENANCE
CF prefilter: at least every 12 months. *
RO osmosis membrane: Every 2 years approx (for waters
to be treated soft (hardness <15 ºHF)).
Postfilter CB: At least every 12 months.
Hygienization: At start-up. At least every 12 months de-
pending on use. Every time components in contact with
water of the equipment are accessed or no water has
been consumed for more than one month.
* Depending on the intended use and characteristics of
the water to be treated.
Maintenance must be carried out by a qualified person-
nel, who must handle the equipment properly, as well as
using original spare parts to maintain the characteris-
tics, guarantee, certifications and performance of the
equipment and thus preserve the quality of the water
dispensed.
ATTENTION: The use of non-original spare parts,
installation outside the limits of operation and
start-up, improper maintenance or use may lead to the
loss of the warranty, as well as the invalidation of the
certifications to which the equipment has been sub-
jected.
Excessive use of any compound ( complete chlorine,
turbidity, hardness, etc...) may cause a reduction in the
lifespan of filters and certain components. These main-
tenance are indicative.
Your distributor will foresee the duration of the consu-
mables according to the characteristics of the water to
be treated and the consumption foreseen in each case.
ATTENTION: All consumables are supplied in indi-
vidual packaging specially designed to guarantee
hygienic storage and transport conditions. Use
extreme caution after removing the consumables from
their packaging and during handling of the various con-
nectors and components.
ATTENTION: Before disassembling the equipment,
provide all the material you will need to carry out
the maintenance operations (read section 5 Insta-
llation) and the space required for this. Work in a we-
ll-lit place, in suitable hygienic conditions and with su-
fficient space to carry out the operations comfortably.
- Change filters properly. Ensure the watertightness of
the joints and the original hydraulic configuration of the
system as recommended by the manufacturer.
- Hygienize the equipment following the instructions
described in the Hygienization Procedure.
- For more information, refer to the technical data
sheet of the equipment. If you have any other ques-
tions, consult your distributor.
ATTENTION: Wear gloves or appropriate personal
protective measures if you use chemicals during
sanitization.