7. IDENTIFICATION AND RESOLUTION OF PROBLEMS
Several possible causes.
1. No water supply.
2. No power supply.
3. Leak sensor activated.
1. Power key partially closed.
2. Filters / membrane in poor con-
dition or exhausted.
Several possible causes.
Several possible causes.
Air in the system. Micro air bubbles
that disappear after a few seconds.
Several possible causes.
1. No water supply.
2. No power supply.
3. Leak sensor activated.
Several possible causes.
1. Deteriorated inlet solenoid valve.
2. Anti-return of deteriorated pro-
duction.
Call for service.
1. Allow the supply to return.
2. Check your home’s power supply. If the
problem is still not solved, call for service.
3. Leak sensor activated. If the leak is unde-
tected, wipe the bottom of the equipment
together with the leak sensor. If it keeps ha-
ppening, call for service.
1. Open completely.
2. Call for service.
Call for service.
Call for service.
It is not a problem. The appearance will fade
as the air inside the equipment is removed.
Call for service.
1. Check the condition of the general key
and the entrance of the equipment.
2. Check the general power supply. If the
problem is not solved, call for service.
3. If the leak is not detected, dry the bottom
of the equipment along with the leak sensor.
If it recurs, call for service.
Call for service.
1. Check and replace.
2. Check and replace.
1. External leakage of
the equipment.
2. No production.
3. Low production.
4. Excessive produc-
tion.
5. Unpleasant taste
and smell.
6. Whitish water
color.
7. Continuous dripping
noise in drain.
8. Equipment does
not start.
9. The equipment
stops and starts
constantly.
10. Equipment cons-
tantly carries water
down the drain.
PROBLEMS POSSIBLE CAUSE SOLUTION
Read the INTERFACE section of the Technical Data Sheet. In case of malfunction, contact the SAT and proceed as
indicated: Close the entrance key. Open the tap to depressurise the system and then disconnect the plug.
Closed Open