1. MAIN FEATURES
APPLICATION
Water treatment
Reverse osmosis
Usage
To improve the characteristics of drinking water (complying with the requirements of the European Drinking Water
Directive 98/83 or its national transpositions in the different Member States of the European Community).
Modifications by reduction or contribution
- Reverse osmosis water treatment is able to reduce concentrations of salts and other substances by high percentages.
- Minimum reduction* of certain compounds and parameters:
Sodium: 90%.
Calcium: 90%.
Sulphate: 90%.
Chloride: 90%.
Total hardness: 90%.
Conductivity: 90%.
* Depending on the characteristics of the water to be treated (at the exit of the membrane). These values may
vary depending on the type of post-filter incorporated in the equipment and/or regulation of the mixing valve (if
incorporated).
2. PRECAUTIONS
ATTENTION: the equipments ARE NOT WATER POTABI-
LIZERS. If the water to be treated comes from a public
supply (and therefore complies with current legisla-
tion), this equipment will substantially improve the quality
of the water.
ATTENTION: If the water to be treated does not come
from a public supply network or originates from an
unknown source, it will be necessary to carry out a
physical-chemical and bacteriological analysis of the water
to ensure its correct potabilisation by applying the techni-
ques and equipment appropriate to each need, PRIOR TO
THE INSTALLATION of the equipment. Contact your distribu-
tor for advice on the most suitable treatment for your case.
TECHNICAL MANUAL
FOR REVERSE OSMOSIS EQUIPMENT
OPERATIONAL LIMITS
PUMP UNIT
Pressure (max./min.):
TDS (max.):
Temperature (max./min.):
Hardness (max.):
4 bar - 1 bar (400kPa-100kPa) .
1500ppm.
38 ºC - 5 ºC.
15 ºHF. **
ATTENTION: If you have any questions regarding the installation, use or maintenance of this equipment, plea-
se contact your dealers technical support service ( S. A. T.).
2.1 CONDITIONS FOR THE CORRECT OPERATION OF THE
EQUIPMENT
- The equipment should not be supplied with hot water
(T>38ºC).
- The ambient temperature should be between 4º and 45ºC.
- For water with salinity higher than 1500 ppm consult your
distributor.
- It is recommended that the water to be treated be decal-
cified or with a maximum hardness of 15 ºHF so as to obtain
optimum performance from the equipment.