5) Referring to the wiring layout shown in the above diagram, connect the battery cable and
bridge terminals to the battery poles. Arrange the cables as shown in the diagram, tighten
the terminals on the poles and cover with Vaseline.
6) Lower the dirty water drum into its work position and fasten it to the detergent tank;
7) When using the machine, follow the instructions below.
5.4.3. Batteries: removal
! DANGER
When removing the batteries, the operator must be equipped with suitable personal
protection devices (gloves, goggles, overalls, safety shoes, etc) to reduce the risk of
accidents. Make sure the switches on the control panel are in the "0" position (off) and
the machine is turned off. Keep away from naked flames, do not short circuit the
battery poles, do not cause sparks and do not smoke. Proceed as follows:
disconnect the battery wiring and bridge terminals from the battery poles.
if necessary, remove the devices fixing the battery to the base of the machine.
lift the batteries from the compartment using suitable lifting equipment.