10. TROUBLESHOOTING
Possible problems affecting the whole machine:
PROBLEM
CAUSE
REMEDY
The brushes
do not turn
you have not used the brush switch
the power supply or motor thermal cutout
connectors are disconnected
the brush motor fuse has blown
the reduction unit is faulty
the motor is faulty
The machine does
not clean evenly
the brush or disks are worn
replace
No detergent
is delivered
the tap lever is in the "CLOSED" position
the detergent tank is empty
the hose delivering the detergent to the
brush is blocked
the tap is dirty or faulty
The detergent flow
does not stop
the tap stays open, because it is
damaged or very dirty
have the tap cleaned or replaced
The suction
motor does
not start
the suction switch is in the ‘0' position (off)
turn the suction switch on
there is no power to the suction motor or
the motor is faulty
check that the motor power connector is
correctly connected to the main wiring;
in the second case have the motor
replaced
the fuse has blown
replace the fuse