EasyManua.ls Logo

IPC Plus D 1915P - Page 28

IPC Plus D 1915P
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
- 28 -
IMPORTANT:
For maintenance and/or repairs, use only original spare parts which o󰀨er the greatest characteristics of quality and
reliability. Failure to use original spare parts frees the manufacturer from all responsibility.
N.B. To reset the indicators, rotate the main switch “A” (g. 8) to the “O” position and then to the “I” position.
FAULTS
Excessive smoke from exhaust.
Inadequate detergent suction.
Water leakage from head.
Water in the oil.
CAUSES
Incorrect combustion.
Fuel contaminated with impurities or
water.
Tap closed.
No detergent.
Element or tube clogged.
Gaskets worn.
Excessive humidity in atmosphere.
REMEDIES
Cleanorreplacediesellters.
Contact Service Centre.
Empty the tank and clean thoroughly.
Cleandiesellters.
Open.
Fill the detergent tank.
Contact Service Centre.
Contact Service Centre.
Replace oil.

Table of Contents

Related product manuals