English
- 27 -
FAULTS
When the switch is turned the cleaner
does not start.
No jet delivered.
The pump turns but does not reach
the rated pressure.
When the lance is turned on the pres-
sure falls and rises. After 10 pulses,
the water cleaner stops and indicator
light“D”(g.7)ashes.
In by-pass or total stop phase, the wa-
ter cleaner shuts down and indicator
light“D”(g.7)ashes.
After the total stop phase, the water
cleaner does not start up and the indi-
cator lights is on.
When the thermostat reaches the
chosen temperature the boiler does
not light.
Indicatorlight“F”(g.7)ashes.
Water not hot enough.
Toomuchsmokefromtheue.
Insucientdetergentsuction.
TROUBLE-SHOOTING
Before carrying out any operations, disconnect the water cleaner from the mains electricity supply via the omni-
polar switch or by unplugging the plug from the socket.
CAUSES
Faulty electric connection.
Thermal protection has tripped.
Faulty water circuit connection.
Cloggedwaterlter.
Mainstapturnedo.
Detergent tap turned on.
Waterintakelterblocked.
Faulty water circuit connection.
Pressure regulation valve is set at
minimum.
Lance nozzle is worn.
Dirty or worn valves.
Detergent intake device on the lance is
turned on.
The nozzle is clogged or deformed.
Insucientsupply.
Micro-leaks of water from the high pres-
sure circuit.
The water cleaner has been unused for
at least 20 minutes and is in a state of
total shutdown.
No fuel.
Fuelltersareclogged.
Thermostat setting.
Cloggedlters.
Boiler coil clogged with scale.
No fuel.
Incorrect combustion.
Impurities or water in the fuel.
Tapturnedo.
No detergent in the tank.
Control on the lance not switched on.
Coil or pipe clogged.
REMEDIES
Check the mains voltage.
Reset (if it trips again, apply to the
technical service centre).
Check it.
Clean it.
Turn it on.
Turnito.
Clean it.
Check it.
Regulate it.
Apply to our technical service centre.
Apply to our technical service centre.
Turnito.
Clean or consult our technical service
centre
Check it.
Contact Service Centre.
Restart by rotating the main switch “A”
(g.7)intothe“O”positionandsubse-
quently into the “I” position.
Check the fuel level in the tank and see
that the fuel intake circuit is clean (no
water).
Changethein-linelter.
Check it.
Cleanthefuellters.
Apply to our technical service centre.
Fill the fuel tank.
Cleanthevariousfuellters.
Empty the tank and clean it carefully.
Cleanthevariousfuellterstoo.
Turn it on.
Fill the detergent tank.
Set the control on the lance.
Apply to our technical service centre.