Blood Pressure Monitor
Instruction Manual
iProvèn BPM-634
Thank you for making iProvèn your top choice. Please read the instructions carefully in order to accurately and
safely utilize this equipment.
The BPM-634 measures the blood pressure and the heart rate and saves the results. It also enables transferring the measurement
using the Bluetooth connection. The BPM-634 o ers real time and accurate readings that are as convenient as possible thanks
to the Oscillometric Measuring method. Blood pressure measurements may not be valid or accurate if they are not performed in
accordance with the instructions provided in this manual, so please keep these instructions handy for future reference.
You can also nd the digital version of this manual on www.iproven.com
It is our passion to develop high quality products for home use. Our products are manufactured at the highest technical
standards of professional quality, durability, and consistency. They are also designed with elegant simplicity in mind, making them
easy to use at home.
To help you get the most from our products, we provide clear instructions with each device. The manual also includes helpful
information that contributes to your overall health awareness.
In order to make sure that our products are tailored to your needs, we welcome your feedback. If you have any issues, questions or
recommendations, please share your thoughts with us at www.iproven.com
iProvèn - Professional Care Brought Home
iProvèn is a Masena Invest brand
Intended use of the BPM-634 blood pressure monitor
The BPM-634 is a digital monitor that is used for measuring blood pressure and heart rate by wrapping the cu around arms of
di erent sizes, within 8¾˝ - 16½˝ (22 cm to 42 cm). The BPM-634 is intended for home use and for adults only.
How this device works
The product uses the Oscillometric Measuring method to detect blood pressure. When the measurement is started, it calibrates
to “zero pressure” which is the natural air pressure. As soon as it starts in ating the wrist cu , the device detects the pressure
oscillations according to the beat-to-beat pulsatile and so it determines the systolic, diastolic pressure and the heart rate.
Irregular Heart Beat detection
The device is equipped with irregular heart beat detection, IHB. The algorithm of the device compares the longest and shortest
intervals of registered pulse waves (the time interval) and calculates the standard deviation. If the di erences in the time intervals
are more than 25% you have an irregular heartbeat and the sign will appear in the display. If the device detects irregular
heartbeat during consecutive measurements and you are following the correct procedure, please consult your doctor.
Intended use of the BPM-634 blood pressure monitor
• The unit should not be used for prolonged monitoring during medical emergencies or operations.
• The cu being in ated for a prolonged time will lead to numbness of wrist and ngers, causing anesthesia, pain and ecchymosis.
• Use the device according to the instructions of this manual to guarantee an e cient performance and durability of the device.
• The cu complies with the requirements of ISO 10993-5:2009 and ISO 10993-10:2010.
• The cu does not cause any potential allergic reaction or contact injury.
• There is no need for calibration during the two years of ‘guaranteed service’.
Setting up the device
1. First make sure you set the time and data correctly so the device can register the results with the correct time;
2. With the monitor OFF, press SET. The time will now show in the display;
3. Hold the SET button for 3 seconds until the “Year” starts blinking;
4. Press or hold MEM to adjust the Year digits that are blinking on the display. Press SET to con rm;
5. Repeat step 2 for setting the Month & Day, Hour & Minutes;
6. Once the Minutes are set, the display will show “mmHg”. This is the standard measurement unit. Press SET to save;
Or press MEM to change to “kPa” and then press SET to save;
7. Once the measurement unit is set, the LCD will show “DONE”. Then the device will show the settings and then shut o .
Taking a measurement
1. Be seated in a quiet and comfortable room, with your arm resting on a at surface;
2. After wrapping the cu (see “wrapping the cu ” section), rest 3 minutes, keep your the palm of your hand upwards, your
back straight and breathe deeply for 5 or 6 times before starting the measurement;
3. Press START to begin the measurement;
4. The monitor will rst calibrate to zero air pressure and then in ate the cu . While in ating the measurements are made;
5. When the measurement is completed the results will appear in the screen. The measurement is also saved in the memory.
Tips for better accuracy
• During the measurement do not move or speak and be seated in a silent room;
• Do not cross your legs during the measurement;
• Do not use the device in a toilet or while doing any sort of activity including talking or moving;
• Do not use the device in a cold environment;
• To get insight in the trend of your blood pressure, it is best to measure your blood pressure at about the same time(s) every day;
• For accurate results, avoid using the device within 1 Hour after eating;
• You shouldn’t measure immediately after drinking tea or co ee and after smoking;
• Avoid measuring after 30 minutes of taking a shower or bath;
• For an accurate and clear result, please measure the same arm every time;
• As a rule of thumb: when you measure your left arm, position the hose in line with the index nger. For even higher accuracy,
make sure the ART sign on the cu is closest to the artery. You can locate the artery by pressing 2 ngers 1 inch above the bend
of your elbow on the inside of your arm. The artery is where you can feel the pulse the strongest.
Wrapping the cuff
When wrapping the cu around your upper arm, make sure that:
• The ART sign of the cu is close to the artery;
• The cu is positioned around an inch from the bent of your arm;
• The cu is snug but not too tight. You have to be able to insert
one nger between the cu and the arm.
Preparing the measurement
The LCD display and the meanings of the symbols
Components of the BPM-634
• Connect the cu by inserting the air plug into the air jack
on the left side of the device.
• Open the battery cover;
• Insert the four AA batteries conform the right polarity;
• Close the battery cover;
Preparing the device
(0.8 - 1.2 )
SYMBOL DESCRIPTION
Systolic pressure High blood pressure
Diastolic pressure Low blood pressure
EXPLANATION
Memory
mmHg
kPa
Measurement Unit of the blood pressure
Measurement Unit of the blood pressure
Low battery Batteries are low and need to be replaced
Current Time
Year/Month/Day, Hour : Minute
(1kPa=7.5mmHg)
(1mmHg=0.133kPa)
Heartbeat
Irregular heartbeat
Motion indicator Indicates detected motion try to avoid
Pulse in beats per minutePulse display
Indicates it is in the memory mode and
the measurement number
Blood pressure monitor is detecting an
irregular heartbeat during measurement
Blood pressure
level indicator
Indicates the blood pressure level
Blood pressure monitor is detecting a
heartbeat during measurement
Deleting the records
In case you want to delete your recorded measurements, please follow these steps:
1. Make sure the monitor is inactive. If the monitor is not yet inactive, rst deactivate it by pressing STOP;
2. Press MEM to go to Memory;
3. Press and hold the MEM button for 3 seconds;
4. “DEL ALL” will start blinking. Press SET to con rm. (Or press STOP to cancel);
5. “DEL DONE” will show, meaning the stored data is deleted. The device will shut o .
Using the memory function
• Every measurement is automatically saved in the memory, with a maximum capacity of 60 measurements;
• Make sure that the date and time are set correctly;
• To view the recorded data press the MEM button while the monitor is inactive;
• If the monitor is not yet inactive, rst deactivate it by pressing STOP;
• Use the buttons MEM for Up and Set for Down to read through the records.
Manual Version: 2.0
Issuing Date: 2018/01/03
©2017. All rights reserved.