28
6
Autom. reset
Man. reset
The thermic overload relay turns off in case of overloading. Because this relay
is installed on automatical reset, after a while the motors are switched back on
automatically.
Installation and type of overload relay
220V
Type value installation
LR2D13149 7-10A 8A
380V
Type value installation
LR2D13109 4-6A 4A
Thermo-magnetic motor protection
When one of the following malfunctions occurs during a program, the central
display will communicate the appropriate error message at the end of the cycle.
E3 (Eprom)
The Eprom is wrong, replace it by another.
Error messages
Remark :
For coin op machines, it is possible that a program number appears on the
right display in combination with E3.
This indicates a wrong price adjustment for this program. A coin value “0
or bigger than “1000” was programmed.
Example : wrong price adjustment for program 5.
E4 (water level)
The appropriate water level was not reached after 15 minutes.
E5 (Heating)
The wash bath did not reach the required temperature after 80 minutes of