Procedure for physically inspecting the MRidium 3850 for damage upon receipt.
Check for electrical integrity and proper pump operation post-maintenance.
Verifying function of all controls and indicators for proper operation.
Procedure for configuring and verifying the wireless communication option.
Description of the initial Service Mode A screen and its components.
Screen for adjusting pump calibration settings and pressure sensors.
Displays detailed information about the battery's condition and performance.
Access point for setting clock, logs, radio, keylock, and language.
Details on maintaining the MRidium 3850/50R, 3851, and 3855.
Verifying PM procedures for the 3850/50R using Service Mode.
Procedures for testing the pump's flow accuracy at various rates.
Verifying PM procedures for the 3851 SideCar using Service Mode.
Procedures for testing the 3851 SideCar's flow accuracy.
Verifying PM procedures for the 3855 Remote Display/Charger.
Guidelines for inspecting and maintaining the battery pack.
Instructions for updating the MRidium pump software.
List of required equipment for detailed system testing and calibration.
List of basic tools required for system tests.
Verifying correct DC power input and voltage levels for the pump.
Procedure for adjusting and verifying pump motor speed settings.
Calibrating and verifying pressure sensor readings for the 3850/50R.
Performing a detailed check of the battery status and health.
Verifying correct DC power input for the 3851 Side Car.
Adjusting and verifying the pump motor speed for the 3851 Side Car.
Testing the bubble detection system on the 3851 Side Car.
Procedure for factory-level calibration of the pump mechanism.
Testing the pump's fluid delivery accuracy at various rates.
Verifying wireless communication setup for 3850R and 3855.
Verifying correct DC power input for the 3855 unit.
Verifying the battery charging system for the 3855 unit.
Verifying the initial power-up sequence and display for the 3855.
Verifying remote control functions of the 3855 unit.
Detailed explanation of the pump's mechanical components and their function.
Explanation of the pump's electronic systems and their interactions.
How the ultrasonic system detects air in the fluid line.
Table of critical error codes and their meanings for pump malfunctions.
| Model | MRidium 3850 |
|---|---|
| Category | Medical Equipment |
| Certifications | CE |
| Occlusion Pressure Settings | Low, Medium, High |
| Infusion Pumps | Syringe Pump |
| Compatibility | MRI compatible |