SAVE THESE INSTRUCTIONS
115 VOLT TRANSFER PUMP
Owner’s Manual
WARNING: Read carefully and understand all ASSEMBLY AND OPERATION
INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
precautions may result in serious personal injury.
Item #50098

Questions and Answers

  • B
    bmckeeAug 3, 2025
    What to do if my Ironton 50098 Water Pump does not start?
    • K
      Kevin FernandezAug 3, 2025
      If your Ironton Water Pump isn't starting, here are a few things to check: * Make sure the cord is fully plugged in. * Check the power at the outlet. If there's no power, turn off the pump and check the circuit breaker. Ensure the circuit's capacity is right for the pump and that there are no other loads on the circuit. Then, reset the breaker. * Inspect the plug for corrosion and clean the prongs if needed. * The motor might be overheated. Unplug the power and wait 10-30 minutes for it to cool down before plugging it back in and restarting the pump.
  • M
    Michele ThompsonAug 13, 2025
    Why is the flow rate of my Ironton Water Pump too low?
    • Q
      qwillisAug 13, 2025
      If the flow rate of your Ironton Water Pump is too low, consider the following: * Check the hose for kinks or coils and straighten it. * Clean the strainer or remove any blockages in the hose. * If the discharge hose is too long, use a shorter one (50 ft. max.). * The impeller might be worn and need replacement. * Low line voltage can be a factor. Ensure the circuit has the right capacity for the pump and that no other loads are on the circuit.
  • V
    Vanessa WhiteAug 25, 2025
    What to do if my Ironton 50098 Water Pump doesn’t prime?
    • W
      Whitney BurchAug 25, 2025
      If your Ironton Water Pump isn’t priming or retaining prime, try these steps: * Check for air leaks in the suction line. Tighten the hose connection or replace the hose washer if necessary. * Remove any clogs from the impeller. * If the impeller is worn or damaged, replace it. * Add water to the pump inlet if the impeller is dry. * Lower the pump if the suction lift is too high. * Straighten the hose if it's kinked or coiled. * Make sure the suction hose is submerged in water, with the strainer at the hose end. * Clean the strainer if it's clogged.

Summary

Intended Use

Important Safety Information

Work Area Safety

Personal Safety

Electrical Safety

Pump Use and Care

Specific Operation Warnings

Electric Shock Hazard

Specific warnings and precautions related to the risk of electric shock, including grounding and outlet requirements.

Grounding

Extension Cords

Assembly

Before Each Use

Operating Instructions

After Each Use

Maintenance

Parts Diagram

Parts List

Troubleshooting

Replacement Parts

Limited Warranty