1. GENERAL CHARACTERISTICS
2. TECHNICAL SPECIFICATIONS
3. WARNINGS
INDEX
GENERAL CHARACTERISTICS
1
TECHNICAL SPECIFICATIONS
2
WARNINGS
3
INSTALLATION EXAMPLES
4
ELECTRICAL CONNECTIONS
5
The I/O logic (code 587.00.0698.0007 – fig 1) is a module that, when connected to the x1R easy lock via
a two-way 3 conductor (Tx, Rx and GND) communication interface, extends its potential, making it possible
to: acquire “Open” and “Close” commands via 2 remote digital inputs;
control 4 relay outputs
Overall dimensions 106x100x58 mm.
Power supply 9/24 VDC
Absorption 100 mA
1 Relay for bolt retracted (in) position
1 door position Relay
1 Relay for latch extracted (out) position
1 Relay for the motorised door opener
control (Relay activated for 1 sec.).
Maximum relay switching voltage:
120VAC/60VDC
Maximum relay switching current: 1A
Maximum relay switching power: 60VA/24W
2 optoinsulated digital inputs (9-24 VAC/DC)
for the “Open” and “Close” commands.
1 POWER ON indication LED.
1 indication LED for each active relay.
1 indication LED for each active digital
input.
1 hook for fixing the DIN bar.
1 two-way 3 conductor (Tx, Rx, GND)
communication channel.
When using the I/0 logic with an x1R Easy lock, before proceeding with
the connection make sure that the black condenser is NOT between
the black and brown wires in the communication cable. If it is remove
it by cutting the terminals. The presence of the condenser (filter)
between the black and brown cables prevents communication between
the x1R Easy lock and the I/0 logic.
4. INSTALLATION EXAMPLES 4.1 INSTALLATION EXAMPLES
5. ELECTRICAL CONNECTIONS
x1R Easy
230 VAC
9/24 VDC
x1R Easy
230 VAC
Installation with Fiam 9VDC – 3 A feeder
1. Door contact supplied with lock
2. Internal facing plate (cod. 98PI0698)
3. Cable gland (cod. 8810.00000 - for openings up to 90°)
(cod. 6013.0000 - for openings up to 180°)
4. Communication cable supplied with the lock
(3 poles: black, brown, blue)
5. I/O Logic (cod. 587.00.0698.007)
6. Fiam 9VDC/2,89A feeder (cod. 587.00.0000.3809)
7. Power supply cable supplied with Fiam feeder
(2 poles: red, black)
Installation with 9/24 VDC – 3A feeder and rechargeable
battery kit / Fiam battery charger
1. Door contact supplied with lock
2. Internal facing plate (cod. 98PI0698)
3. Cable gland (cod. 8810.00000 - for openings up to 90°)
(cod. 6013.0000 - for openings up to 180°)
4. Communication cable supplied with lock
(3 poles: black, brown, blue)
5. I/O Logic (cod. 587.00.0698.007)
6. Set of rechargeable Fiam batteries (cod. 582.00.6000.0016)
7. Power supply cable supplied with Fiam battery holder
(2 poles: red, black)
8. Fiam battery charger (cod. 582.00.6001.0016)
9. Fiam 230/12 VAC transformer (cod. 582.00.0698.0000)
10. Fiam battery holder (cod. 587.00.0698.0000)
11. External 9/24 VDC 2A power supply (not supplied).
1
2
3 4
5
1
2
3
4
5
6
7
8
9
10
11
6
7
J2
J1
J3
Note: each digital inputs
has a statud LED.
Note:
each relay has a status LED.
LED Power “ON”
9/24
VAC/VDC
9/24
VAC/VDC
6
7
8
9
P1
(”OPEN” button
not supplied)
P2
(”CLOSE” button
not supplied)
1
2
3
4
5
10
11
12
13
14
15
16
17
C
NO
C
NO
C
NO
C
NO
RL1
RL1
RL2
RL2
RL3
RL3
RL4
RL4
Motorised latch bolt
position relay
Bolt retracted
position relay
Door position relay
Relay (1 sec. impulse)
controlling motorised
“door opened”
POSITIVE FEED
9/24 VDC
NEGATIVE FEED
9/24 VDC
EARTH
Before switching on the
power to the I/O Logic
and the x1R Easy lock
connect the communication
cable.
Communication cable
with 3 poles: black,
brown and blue supplied
with the x1R Easy lock.
BLACK WIRE
BROWN WIRE
BLUE WIRE
The 3 poles communication
cable supplied with the lock (n° 4
paragraph 4) is 4 meters long; if
you need to extend the cable,
the maximum length is 15
meters, using an AWG25 cable.
Note: the bridges (JP1,
JP2, JP3, JP4) can be used
to configure the
respectives relay to be NO
(factory setting) or NC (by
moving the bridge to the
1-2 position.
x1R Easy
www . iseo.com
x1R Easy
®
ELECTRONIC SUPPORT SERVICE
www.iseozero1.com
Non contractual document. Subject to change.
Documento non contrattuale. Con riserva di modifica.
Codice: 6000006980007 Installation Manuale I/O LOGIC.
(Eng/It) Rev. 002 data 14/02/2015
Side
view
Top
View
100 mm.
105 mm.
58 mm.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Iseo x1R Easy and is the answer not in the manual?

Iseo x1R Easy Specifications

General IconGeneral
BrandIseo
Modelx1R Easy
CategoryDoor locks
LanguageEnglish

Related product manuals