OPERATING AND INSTALLATION MANUAL
CONVERTER
ML 210
Release number: 210_EN_IS_R8_3_9X The last three digits of file name identify the
software version which the manual refers to; it is visualized at the instrument start up, or by
specific function on DIAGNOSTIC menu.
Question and Answer IconNeed help?

Do you have a question about the ISOIL ISOMAG ML 210 and is the answer not in the manual?

ISOIL ISOMAG ML 210 Specifications

General IconGeneral
BrandISOIL
ModelISOMAG ML 210
CategoryMedia Converter
LanguageEnglish

Summary

Introduction and Safety Information

Safety Informations

Details critical safety precautions and warnings for instrument handling and installation.

Safety Symbols and Conventions

Explains safety symbols and their meanings: DANGER, WARNING, and NOTES.

Technical Characteristics

Electric Characteristics

Covers instrument classification, power supply, voltage, frequency, and Pmax.

Environmental Use Conditions

Details altitude and humidity range for installation.

Ambient Temperature

Specifies minimum and maximum operating temperatures.

Data Plate Information

Lists key technical information found on the device's data plate.

Overall Dimensions and Torques

Weight Specifications

Provides weight specifications for compact and separate versions.

Torque Requirements for IP Rating

Specifies torques required for housing's IP degree.

Electrical Connections

Grounding Instructions

Emphasizes correct grounding for equipment and liquid equipotentiality.

Converter Power Supply Connections

Details power supply connections for different versions.

Compact/Separate Terminal Block Layout

Panel Version Terminal Block Layout

Converter to Sensor Wiring

Separate Version Wiring Diagram

Shows wiring diagram for separate converter and sensor connections.

Sensor with Preamplifier Wiring

Details wiring for sensors with a preamplifier.

Optional Modules Overview

Non-Relay Module Options

Lists optional modules like ME200-ME204 and data logger/protocols.

Terminal Connection Legend

Defines abbreviations used for terminal connections.

Optional Relay Modules

Relay Module Legend

Defines abbreviations for relay module connections.

Compact/Separate Relay Terminal Block

Shows terminal block configuration for relay modules.

Panel Relay Terminal Block

Shows terminal block configuration for panel relay modules.

Inputs and Outputs Overview

Digital Input Configuration

Illustrates input configurations for external and internal power supplies.

Input Operation Modes (ON/OFF)

Generic Input Functions

Details auto-calibration, reset totalizers, block totalizers, and range change.

Batch Operation (Input 1 or 2)

Batch Operation (Input 1 and 2)

Output Wiring Details

On/Off Output Wiring (1250Hz)

Describes opto-insulated outputs for 1250Hz frequency signals.

On/Off Output Wiring (12500 Hz)

Describes opto-insulated outputs for 12500Hz frequency signals.

4-20mA Output Wiring

Details the 4-20mA output specifications and failure detection.

Converter Access and Status

Flags and LED Interpretation

Explains the meaning of display flags and status LEDs.

LED Status Interpretation

Describes the interpretation of LED states (permanent, flashing).

Keyboard Operation Guide

Blind Configuration Method

Start-up Visualization Pages

Currency Function Display

Flow Rate Display Information

Access Code Management

DIP Switch Configuration

Quick Start Menu Usage

Configuration Menu Access Methods

ISOCON Interface Configuration

Explains configuration using the ISOCON software.

Keyboard Configuration Access

Describes accessing menus via the keyboard (Quick Start and Main Menu).

Modify Full Scale via Quick Start Menu

Modify Full Scale via Main Menu

Programming Functions Overview

Sensor Programming Functions

Configuration options for sensor type, diameter, and calibration.

Scales Programming Functions

Settings for full scale values, units of measure, and pulse outputs.

Measure Programming Functions

Filter settings for measurement accuracy and response time.

Alarms Programming Functions

Configuration of alarm thresholds and output values for failures.

Input Programming Functions

Output Programming Functions

Communication Programming Functions

Display Programming Functions

Data Logger Functions

Diagnostic Functions

Internal Data Functions

Batch Function Setup

Detailed Sensor Functions

Detailed Scales Functions

Scales and Pulse Functions

Measure Filter Settings

Advanced Measure Filters

Filter Response Diagrams

Scale and Energy Saving Functions

Automatic Scale Change

Explains automatic scale switching based on flow rate.

Energy Saving Mode

Describes the energy saving function for battery-powered operation.

Alarm Configuration and Outputs

Current Output on Failure

Sets the output current value for various failure conditions.

Frequency Output on Failure

Sets the frequency output value for various failure conditions.

Batch Safety Timer

Sets a maximum time for batch operations to prevent alarms.

Input Programming Functions

Output Programming Functions

Current Output Scaling

Display Contrast Adjustment

Totalizer Conversion Factor

Totalizer Reset Procedures

Data Logger Date and Time Setting

Diagnostic: Meter Calibration

Diagnostic: Auto-Test Function

Diagnostic: Flow Rate Simulation

Batch Sample and Compensation Settings

Batch Compensation Limit and Value

Batch Pre-Batch Value Setting

Batch Auto-Batch Function

Batch Formula Auto-Selection

Batch Static Consent Mode

Batch Function Configuration Steps

Batch Start/Stop Control

Batch Operation Important Notes

Alarm Messages and Causes

Anomaly Codes and Service Actions

Appendix: Display Rotation

Display Rotation Procedure

Step-by-step guide to rotate the display for better visibility.

Service Return Form

Conformity Declaration Details

Company and Distributor Addresses