kg/cm2 (psi)
4BGl
4BGlT,
6BG1,GBGlT
Injection Starting
150
185
Pressure
(2134)
(2630)
WARNING
TEST FLUID FROM THE NOZZLE TESTER WILL SPRAY
OUT UNDER GREAT PRESSURE.
IT
CAN EASILY
PUNCTURE A PERSONS SKIN. KEEP YOUR HANDS
AWAY FROM THE NOZZLE TESTER AT ALL TIMES.
Spray Condition Check (During Injection
Nozzle Tester
Operation)
1. Tighten the
cap nut.
2. Check the injection nozzle starting pressure.
3. Check the injection nozzle spray condition.
Operate the injection nozzle tester hand
lever 4 to 6
times a second while looking for abnormal injection
nozzle spray conditions.
Refer to the illustration for different spray
conditions.
(1) Good
(2) Bad (Restrictions
in
orifice)
(3) Bad (Dripping)
5l
Feed Pump Strainer
1. Remove the joint bolt.
2. Use a screwdriver to remove the strainer.
3, Wash the strainer in clean diesel fuel.
0