RCD
30
Note: ST007 can detect Neutral-Earth reversal only if
there is RCD device by making current leakage higher
then 30mA between Live (L) to Neutral (N).
Warning
If there is no RCD or the RCD is damaged the
ST007 will
consider the test as correct even though it might be not!
5.1
Correct result
The RCD will not be tripped.
5.2
Fail result
The RCD will be tripped.
9
In case that you have finished the Neutral (N) / Earth (PE)
Reversal Test you can proceed to RCD Test.
6.
MANUAL TEST - RCD TESTING
Start the RCD test:
Press
RCD TEST
Button