EasyManuals Logo

ITI SIMON User Manual

Default Icon
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
Alarm Sirens and Lights
Exterior and interior sirens make 3 different alarm sounds on the premises, each indicating a different type of alarm. Sirens will
time-out and stop sounding after the siren timeout (programmable by the installer). System controlled lights also indicate the type
of alarm.
Use the following table to understand alarm sounds and controlled lights.
Numeric Pager
You may program your security system to send a numeric message indicating system activities to your pager. The system will
send the message twice. See “Programming Your System” on page 11.
Alarm Type Interior Siren Sound Exterior Siren Sound System Controlled Lights
(Not Included in Basic Model)
Fire (Temporal 3) 3 siren pulses then off
for 2 seconds, 3 siren
pulses then off for 2
seconds, . . .
3 siren pulses then off
for 2 seconds, 3 siren
pulses then off for 2
seconds, . . .
On steady
Intrusion On steady On steady Flashing
Emergency Fast on-off _________________ On steady
Panel Indicator Lights
Use the following table to understand the panel indicator lights.
Button When the Button Light is On When the Button Flashes
ARM Doors & Windows Doors/Windows armed Doors/Windows armed &
No Entry Delay on
ARM Motion Sensors Motion Sensors armed Motion Sensors armed &
Latchkey on
DISARM System disarmed System subdisarmed
SYSTEM STATUS System trouble or Open Sensor System in alarm
CHIME Doors Door will cause chime _____________________
CHIME Special Motion
(Not Included in Basic Model)
Motion will cause chime _____________________
LIGHTS Time Activated
(Not Included in Basic Model)
Light schedule is on _____________________
LIGHTS Sensor Activated
(Not Included in Basic Model)
Sensors will cause light to go on _____________________
Use the following table to determine what the numeric message is reporting.
Reports Numeric Message Reports Numeric Message
Phone Test -101 -101 Intrusion -108 -108
AC Power Restoral -102 -102 Fire -109 -109
AC Power Failure -103 -103 Disarming -110 -110
Latchkey -104 -104 Arming -111 -111
No Activity -105 -105 Fail to Disarm -112 -112
Panic Code -106 -106 Fail to Arm -113 -113