EasyManua.ls Logo

IWAKI MDK Series User Manual

IWAKI MDK Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Read this manual before use of product
Instruction Manual
(Europe Edition)
IWAKI Magnetic Drive Pump
MDK Series
T511-2 '17/04
http://www.iwakipumps.jp
IWAKI CO.,LTD. 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 Japan
TEL: +81 3 3254 2935 FAX: +81 3 3252 8892
European ofce
/ IWAKI Europe GmbH
TEL: +49 2154 9254 0 FAX: +49 2154 9254 48
Norway
/ IWAKI Norge AS
TEL: +47 23 38 49 00 FAX: +47 23 38 49 01
Australia
/ IWAKI Pumps Australia Pty Ltd.
TEL: +61 2 9899 2411 FAX: +61 2 9899 2421
Germany
/ IWAKI Europe GmbH
TEL: +49 2154 9254 50 FAX: +49 2154 9254 55
Sweden
/ IWAKI Sverige AB
TEL: +46 8 511 72900 FAX: +46 8 511 72922
China (Hong Kong)
/ IWAKI Pumps Co., Ltd.
TEL: +852 2607 1168 FAX: +852 2607 1000
Holland
/ IWAKI Europe GmbH (Netherlands Branch)
TEL: +31 74 2420011 FAX: +49 2154 9254 48
U.K.
/ IWAKI Pumps (U.K.) LTD.
TEL: +44 1743 231363 FAX: +44 1743 366507
China (Guangzhou) / GFTZ IWAKI Engineering & Trading Co., Ltd.
TEL: +86 20 84350603 FAX: +86 20 84359181
Italy
/ IWAKI Europe GmbH (Italy Branch)
TEL: +39 0444 371115 FAX: +39 0444 335350
U.S.A.
/ IWAKI America Inc.
TEL: +1 508 429 1440 FAX: +1 508 429 1386
China
/ IWAKI Pumps (Shanghai) Co., Ltd.
TEL: +86 21 6272 7502 FAX: +86 21 6272 6929
Spain
/ IWAKI Europe GmbH (Spain Branch)
TEL: +34 93 37 70 198 FAX: +34 93 47 40 991
Argentina
/ IWAKI America Inc. (Argentina Branch)
TEL: +54 11 4745 4116
Korea
/ IWAKI Korea Co., Ltd.
TEL: +82 2 2630 4800 FAX: +82 2 2630 4801
Belgium
/ IWAKI Belgium N.V.
TEL: +32 13 670200 FAX: FAX: +32 13 672030
Singapore
/ IWAKI Singapore Pte Ltd.
TEL: +65 6316 2028 FAX: +65 6316 3221
Taiwan
/ IWAKI Pumps Taiwan Co., Ltd.
TEL: +886 2 8227 6900 FAX: +886 2 8227 6818
Denmark
/ IWAKI Nordic A/S
TEL: +45 48 242345 FAX: +45 48 242346
Indonesia
/ IWAKI Singapore (Indonesia Branch)
TEL: +62 21 6906606 FAX: +62 21 6906612
Thailand
/ IWAKI (Thailand) Co., Ltd.
TEL: +66 2 322 2471 FAX: +66 2 322 2477
Finland
/ IWAKI Suomi Oy
TEL: +358 9 2745810 FAX: +358 9 2742715
Malaysia
/ IWAKIm SDN. BHD.
TEL: +60 3 7803 8807 FAX: +60 3 7803 4800
Vietnam
/ IWAKI Pumps Vietnam Co., Ltd.
TEL: +84 613 933456 FAX: +84 613 933399
France
/ IWAKI France S.A.
TEL: +33 1 69 63 33 70 FAX: +33 1 64 49 92 73

Questions and Answers:

IWAKI MDK Series Specifications

General IconGeneral
BrandIWAKI
ModelMDK Series
CategoryWater Pump
LanguageEnglish

Summary

Safety Section

Types of Symbols

Explains the meaning of various warning and caution symbols used throughout the manual.

Export Restrictions

Details information regarding the control of technical data export according to international regulations.

Warning Instructions

Critical safety instructions covering electrical shock, protective gear, pump modification, and hazardous liquid handling.

Caution Instructions

Operational precautions including personnel qualifications, intended use, ventilation, and preventing dry running.

Electrical and Installation Safety

Guidance on grounding, GFCI installation, pump storage conditions, foreign matter, and proper disposal.

Outline of Product

Unpacking and Inspection

Procedures for checking the pump after unpacking and verifying it is free from transport damage.

Operating Principle

Explanation of the functional mechanism of the magnetically driven turbine pump.

Model Identification

Guide to identifying specific pump models based on their nomenclature and specifications.

Specifications

Technical data including bore size, standard flow rates for 50/60Hz, gravity limit, and motor power.

Construction and Material

Overview of the pump's internal construction and the materials used for key components.

Outline Dimensions

Presentation of the physical dimensions and measurements for each pump model.

Performance Curves

Graphical representation of pump performance characteristics under varying conditions.

Construction and Parts Names

Detailed illustration and naming of all pump components for reference.

Installation

Precautions before Use

Essential safety measures for starting, stopping, and general operations prior to pump activation.

Plumbing Guidelines

Instructions for connecting pipes, tightening torque, and managing piping load and momentum.

Electrical Wiring

Requirements and procedures for safe and correct electrical connections to the pump motor.

Operation

Precautions on Operation

Critical safety advice for pump operation, including avoiding dry running and checking rotational direction.

Preparation for Operation

Steps to perform before operating the pump for the first time or after a long period of disuse.

Operation Procedures

Detailed steps for starting the pump, adjusting discharge pressure, and monitoring performance.

Stopping the Pump

Procedures for safely stopping the pump and precautions for periods of non-use or power failure.

Maintenance

Troubleshooting Guide

A guide to identifying and resolving common pump problems, their causes, and countermeasures.

Maintenance and Inspection

Procedures for performing daily and periodic inspections and routine maintenance on the pump.

Consumable Parts

Information on replaceable parts, their expected life, and replacement recommendations.

Disassembling and Assembling

Step-by-step instructions and required tools for pump disassembly and reassembly.