Capter 1 Overview

1.1 Features

Details the key features of the CS-3000 series instrument, including voltage, current, and model variations.

Capter 2 Name and Function of Each Part (Outline)

2.1 Name and outline of each part on front panel

Identifies and describes the components and controls on the instrument's front panel.

Capter 3 Function Setting and Basic Operation

3.1 Measurement operation flow

Describes the sequence of operations for performing measurements with the instrument.

3.2 Setting up this instrument

Details the environmental and positional requirements for instrument setup and installation.

3.3 Preparation before measurement

Covers essential steps before measurement, including connections and powering on.

3.5 Setting with function keys and knobs

Details how to use the front panel keys and knobs for setting parameters and navigating menus.

3.6 Setting step generator

Covers the configuration of the step generator for voltage or current step signals.

3.7 Setting collector supply

Explains how to set the collector supply mode, voltage, and current parameters.

3.8 Setting measurement

Describes the different measurement modes: REPEAT, SINGLE, and SWEEP.

3.9 Setting with HORIZONTAL knob; VERTICAL knob

Details how to adjust horizontal and vertical axis settings for waveform display.

3.10 Setting DISPLAY part menus

Explains various display settings and options, including cursors and zoom.

3.11 Setting SYSTEM part menus

Covers system-level configurations like utilities, copy, save/recall, and options.

Capter 4 Characteristics Measurement

4.1 Quick start guide

Provides basic instructions for setting up and performing measurements on common devices.

4.1.1 Diode measurement

Details procedures for measuring diode forward characteristics, ON resistance, and reverse breakdown.

4.1.2 Transistor measurement

Covers measurement of transistor IC-VCE, hFE, IC-VBE, IC-IB, and IB-VCE characteristics.

Capter 6 Specifications

Iwatsu CS-3100 Specifications

General IconGeneral
Bandwidth100 MHz
Number of Channels2
Sweep Time5 ns/div to 0.5 s/div
Trigger ModesAuto, Normal, Single
Display6 inch CRT