EasyManua.ls Logo

Iwatsu SC7101 - DISPLAY UNIT Sescsscseccccccccscscseces

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC-7101
/SC-7102
2-3.
DISPLAY
UNIT
Section
2
Operating
Information
11
digits
LED
to
shows
measured
results
of
input
signals.
Turns
on
while
GP-IB
remote
status.
Turns
on
while
the
|
measurement
overflows.
Gate
Turns
on
while
the
=
4
oogc000
Indicates
the
high
stability
crystal
oscillator
with
a
thermostat
(SC-7102)
a
ETS
EI
TTT
>
oven
6
z
EXPONENT
gate
is
open.
Display
of
Hysteresis
in
a
Mantissa
In
measurement
of
the
signal
of 10
MHz
or
less,
resolution
is
determined
according
to
the
mea-
surement
time.
Thus,
if
MSD
value
of
the
mea-
sured
results
changes
from
9
to 10
or
vice
versa,
read-out
of
the
results
becomes
difficult,
since
the
position
of
decimal
point
and
exponent
change
while
the
number
of
digit
displayed
remains
same.
To
solve
this
problem,
when
MSD
value
changes
from
9
to
10,
the
display
of
the
mantissa
is
shifted
to
left
by
1
digit
to
blank
the
lowest
digit.
(For
the
external
output
data,
0
is
added
to
the
lowest
digit).
When
MSD
value
changes
from
10
to
9,
the
display
of
the
mantissa
is
shifted
to
right
by
omitting
1
digit.
Through
the
above
operations,
hysteresis
is
provided
with
display
for
easy
read-out.
If
this
operations
are
performed
8
times
continu-
outly
or
if
the
MSD
value
becomes
any
one
of
2
through
8,
results
will
be
displayed
without
such
operations.
In
the
RECIPROCAL
mode
measurement,
where
the
result
is
obtained
by
calculating
the
count
data,
there
may
be
1
digit
difference
in
the
effective
digit
due
to
calculated
error
even
in
measurement
in
the
same
range.
Also,
in
such
a
case,
the
same
processes
as
above
are
performed
to
ensure
easy
read-out.
—
Mantissa
Exponent
On
Displays
*
The
highest
9
digits
indicate
the
mantissa.
However,
in
the
case
when
the
measured
result
is
negative,
the
first
digit
(the
left-end
of
the
mantissa
display)
takes
"-"
sign
and
the
display
of
the
measured
result
is
maximum
8
digits.
*
The
lowest
two
digits
(10th
and
11th
digits
from
the
left)
display
the
sign
of
the
exponent
and
1
digit
of
the
exponent.
The
displays
of
the
exponent
are
by
such
multi-
ples
of
3,
as,
-9, -6,
-3,
0,
3, 6,
9.
When
the
sign
of
the
exponent
is
+,
this
position
is
left
blank.
*
For
display
of
the
mantissa,
the
leading
zero
blanking
occurs.
°
When
the
measurement
overflows,
normally
the
OVER
LED and
the
date
display
indicates
overflow
mark
"Uuueee".
However,
though
counting
has
been
10
or
more
digits,
the
data
display
shows
the
mantissa
in
9
digits
from
the
lowest
digits
and
indicates
the
overflow
by
turning
on
the
OVER
LED.