12/14
Err-05
运行时过压
Over voltage
during
operation
Power off and check input voltage is higher than 264V or not.
Please restart when voltage is normal if the input voltage is higher than normal one.
Please replace control box and inform the supplier if it can’t work.
Err-07
电流检测回路
故障
Circuit problem
关闭系统电源,30 秒后重新接通电源观察是否能正常工作。重试几次,若该故障频
繁出现,请更换控制器并通知厂方。
Power off and then restart after 30S. Please replace control box and inform the supplier if
it can’t work after restart for a few times.
Err-08
电机堵转
Motor stuck
断开控制器电源,检查电机电源输入插头是否脱落、松动、破损,是否有异物缠绕
在机头上。排除后重启系统仍不能正常工作,请更换控制器并通知厂方。
Power off and check if input plug is loose, broken or winded by stuff or not.Please
replace control box and inform the supplier if it can’t work.
Err-09
制动回路故障
Brake circuit
problem
关闭系统电源,检查电源板上白色的制动电阻接头是否松动或脱落,将其插紧后重
启系统。若仍不能正常工作,请更换控制器并通知厂方。
Power off and check if the white brake resister is loose or not, then plug in. Please
replace control box and inform the supplier if it can’t work.
Err-12
电机初始角度
检测故障
Initial angle of
motor problem
请断电后再尝试 2-3 次,若仍报故障,请更换控制器并通知厂方。
Try 2-3 times after power off. Please replace control box and inform the supplier if it
can’t work.
Err-13
电机光编码器
信号丢失故障
Encoder signal
problem
关闭系统电源,检查电机传感器接头是否松动或脱落,将其恢复正常后重启系统。
若仍不能正常工作,请更换控制器并通知厂方。
Power off and check motor sensor is loose or not. Restart after recover it. Please replace
control box and inform the supplier if it can’t work.
Err-14
主板读写
EEPROM 故障
Main board
writing
EEPROM
problem
关闭系统电源,30 秒后重启系统,若仍不能正常工作,请更换控制器并通知厂方。
Power off and restart system after 30S.
Please replace control box and inform the supplier if it can’t work.
Err-15
电机超速保护
Motor
over-speed
protection
Err-16
电机反转
Motor
conversion
Err-18
电机过载
Motor overload
4.2 安全报警表 SAFETY ALARM SHEET
报警代码
Alarm code
代码含义
Meaning
解决措施
solutions
A-UP 翻抬开关报警
Machine head flop alarm
摆正机头,确保翻抬开关复原
Make sure the machine head is in right position and reset switch