E r r - 1 0
HMI 通讯故障
HMI communication error
检查控制面板与控制器的连线是否脱落、松动、断裂,将其恢复正常后重启
系统。若仍不能正常工作,请更换控制器并通知厂方。Check the connection
of control panel and controller, whether loose or fall offmake it right and then
restart it. If still not work, please replace the control box, and inform service
center
E r r - 1 1
机头停针信号故障
Machine head needle
position signal breakdown
检查机头步信号装置与制器的连线是否松动将其恢复正常重启
Check the connection
between machine head frame synchronization unit and controller, If it is loose,
make it right then restart. If still not work, please replace the control box, and
inform service center
E r r - 1 2
电机初始角度检测故障
Motor initial angle
detection error
请断电后再尝试 2-3 次,若仍报故障,请更换控制器并通知厂方。Power off
then try 2 to 3 timesIf still report error, please replace the control boxes and
inform service center
E r r - 1 3
电机 HALL 故障
Motor HALL breakdown
关闭系统电源,检查电机传感器接头是否松动或脱落,将其恢复正常后重启
系统。若仍不能正常工作,请更换控制器并通知厂方。
Power off
check the
motor sensor connector, If it is loose or fall off, make It right then restart
If still
not work, please replace the control box, and inform service center
E r r - 1 4
DSP 读写 EEPROM 故障
DSP read EEPROM error
关闭系统电源,30 秒后重启系统,若仍不能正常工作,请更换控制器并通
知厂方。Power off then restart it after 30 second. If still not work, please replace
the control box, and inform service center
E r r - 1 5
电机超速保护
Motor overspeed
protection
E r r - 1 6
电机反转
Motor contrarotation
E r r - 1 7
HMI 读写 EEPROM 故障
HMI read EEPROM error
E r r - 1 8
电机过载
Motor overdrive
E r r - 1 9
翻台开关报警
Turn off switch warning
摆正机头,确保翻台开关复原
Adjust the machine head
make sure the recovery
of turn off switch.