J-200
To ensure optimum performance, clean and reuse the skimmer bag and 
lter cartridge once a month or as necessary, depending on use.
J-210 models include lters on their footwell suction covers  
(shown right) that prevent debris from entering the pump and 
the massage selector(s), when operating. These lters must 
remain in place to protect these components from debris 
entrapment/damage. They should be cleaned every 2 months, 
or when weak pump performance is observed.
 
These model spas are equipped with a skimmer bag and one high 
performance pleated lter cartridge located under the lter cover as 
illustrated below. Debris are ltered by the optional circulation pump 
(when equipped) drawing water through the skimmer bag and lter 
cartridge 24-hours a day, or by jets pump 1 when running a programmed 
lter cycle or when manually activated by spa use. Combined, both 
lters provide unsurpassed water quality by trapping surface oils and 
suspended particles. The lter cartridge should be cleared once a month, 
or as needed for optimum performance.
 
Refer to steps A-J below for complete lter cleaning/replacement 
instructions.
A
   DANGER: TURN POWER TO SPA OFF! TO DECREASE 
NEVER OPERATE SPA WHEN FILTER IS NOT PROPERLY 
INSTALLED OR IF SKIMMER ASSEMBLY IS DAMAGED OR 
ALTERED!
B
  Lift upward on lter 
skimmer cover handles 
to remove it from 
mating retainer clips.
C
 
Remove skimmer bag 
from clips, then clean 
out debris.
D
 
Rotate lter 
cartridge handle 
counterclockwise to 
unthread lter cartridge 
from mating wall tting.
33