31
LX Collection
Standard Filtration/Heating Modes
F0 5 minutes of ltration per day (one 5 minute “Blow-Out”
cycle every 24 hours to purge all plumbing lines)
F1 1 hour of ltration per day (one 30-minute cycle every 12
hours); This is the factory default setting.
F2 1.5 hours of ltration per day (one 30-minute cycle every
8 hours)
F3 2 hours of ltration per day (one 30-minute cycle every 6
hours)
Economy Filtration/Heating Modes
F4 1 hour of ltration/heating per day (one 30-minute cycle
every twelve hours)
F5 1.5 hours of ltration/heating per day (one 30-minute
cycle every eight hours)
F6 2 hours of ltration/heating per day (one 30-minute cycle
every six hours)
Lock Modes
L1 Lock Out: Disables all spa functions to permit lter
cleaning.
L2 Lock Mode: Disables the jets to prevent unauthorized use
of spa. Filtration/heating cycle will continue to operate
as programmed in this mode. The temperature display
ashes when this function is enabled. Example: The “F3” ltration/
heating cycle was enabled prior to choosing lock mode. The spa
continues to perform the “F3” cycle until lock mode is canceled,
allowing another cycle to be selected.
Note: To exit a Lock Mode you will need to re-enter the ltration/heating
modes and select a cycle from F0-F6.
To set a time for the rst ltration/heating cycle, simply turn power on to
the spa two minutes prior to the desired time. Example: If you desire your
rst ltration/heating cycle to begin at 10:00 AM turn off power to the spa
and turn it back on again at 9:58 AM.
Note: Start time is approximate and may vary slightly from day to day.