FloPro Series Pumps Installation and Operation Manual
3.1.3 Replacement of Existing Pump
Jandy FHP pumps can easily replace several
other pumps: the Hayward
®
Super Pump
®
, Pentair
®
SuperFlo
®
, Pentair
®
WhisperFlo
®
, Jandy PlusHP (PHP),
and Jandy MaxHP (MHP).
To replace the Pentair
®
WhisperFlo
®
, Jandy PHP,
or Jandy MHP, use the FHP’s adjustable base. The FHP
base (and its spacers) increase the total height of the
pump and the height of the suction side of the pump.
See Table 1.
Table 1. FHP Dimensions
Base Configuration
Suction Side
Height
Pump
Height
Pump without Base 7 ¾" 12¾"
Pump with Base 8"13"
Pump with Base and Spacers 9"14"
3.1.3.1 Hayward
®
Super Pump
®
and
Pentair
®
SuperFlo
®
The Jandy FHP can replace a Hayward
®
Super
Pump
®
or a Pentair
®
SuperFlo
®
without using the FHP
base. See Figure 2.
7 3/4"
12 3/4"
Figure 2. Place FHP Directly on Equipment Pad
8 7/8"
13 7/8"
Figure 3. Place FHP with Base on Equipment Pad
X
X
Cut
spacers
at X.
Figure 4. Cut Sets of Spacers Out of Base
Figure 5. Snap Spacers into Place
9 1/8"
14 1/8"
Figure 6. Place FHP with Base and Spacers on
Equipment Pad
3.1.3.2 Pentair
®
WhisperFlo
®
Pump
To replace a Pentair
®
WhisperFlo
®
pump with a
Jandy FHP, place the FHP base on the equipment pad
and place the FHP on the base, as shown in Figure 3.
3.1.3.3 Jandy PlusHP (PHP) and
Jandy MaxHP (MHP)
To replace a Jandy PHP or Jandy MHP pump with a
Jandy FHP, use the FHP base with spacers.
1. Using a hand cutter tool, cut the plastic bars
connecting the top and bottom sets of spacers, as
shown in Figure 4.
2. Push the two (2) top spacers and two (2) bottom
spacers out of the base.
3. Align the pins in the four (4) spacers with the
holes in the base and snap the spacers into place,
as shown in Figure 5.
4. Place the FHP on the base assembly. See Figure 6.
Hayward and Super Pump are registered trademarks of Hayward
Industries, Inc.
Pentair is a registered trademark of Pentair, Inc.
SuperFlo and WhisperFlo are registered trademarks of Pentair Water
Pool and Spa, Inc.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy FHPM FloPro Series and is the answer not in the manual?

Jandy FHPM FloPro Series Specifications

General IconGeneral
BrandJandy
ModelFHPM FloPro Series
CategoryPower Pump
LanguageEnglish

Related product manuals