Model LD Pool and Spa Heater
Page 5
Figure 1. General Configuration.
* Ratings shown are for both natural and propane gas.
Venting Dimensions
Model Heater U.S. Indoor or Firing Rate / Hr.*
Width
Vent Outdoor
CAN Outdoor (1,000's)
Diameter Dim "H"
Shelter Dim "H"
in (cm) in (cm) in (cm) in (cm) BTU (kcal)
LD125 15 (38) 5 (13) 17 3/8 (44) 16 1/4 (41) 125 (32)
LD175 18 (46) 6 (15) 18 (46) 24 1/8 (61) 175 (44)
LD250 22 1/2 (57) 7 (18) 18 1/4 (47) 25 1/4 (64) 250 (63)
LD325 26 3/4 (68) 8 (20) 18 7/8 (48) 26 1/2 (67) 325 (82)
LD400 31 3/4 (81) 9 (23) 21 1/2 (55) 27 1/2 (70) 400 (101)
2.3 Location Requirements
2.3.1 Introduction
CAUTION
When pool equipment is located below the pool
surface, a leak from any component can cause large
scale water loss or flooding. Jandy Pool Products,
Inc. cannot be responsible for such water loss or
flooding or resulting damage.
ATTENTION
Lorsque l’équipement d’une piscine est situé sous la
surface de l’eau, une fuite provenant de n’importe
quel élément peut causer une perte d’eau importante
ou une inondation. Jandy Pool Products, Inc. n’est
pas responsable des pertes d’eau, des inondations
ou des avaries causées par une installation ou un
entretien inadéquat.
The Jandy Lite2 LD heater may be installed
indoors or outdoors as outlined in later sections.
Location of the heater below or above the pool water
level affects operation of its water pressure switch.
See sections on water piping and heater start-up for
more information about this.