EasyManua.ls Logo

Janus C4 I/O Blade - User Manual

Janus C4 I/O Blade
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
Version 1.0 February 2019
Specication
The Janus C4 I/O Blade is a plug-in unit that can be
purchased with either the Janus C4 Single-Blade
Controller (Part No: JC4-ADV-C2-SNG) or the Janus C4
Multi-Blade Controller (Part No: JC4-ADV-C2-MLT).
Each I/O Blade enables the connection of up to 8
supervised inputs and 8 volt-free relay outputs.
Clearly labelled connectors simplify the task.
Overview
Janus C4 IO16 Blade
Aux Inputs
5V pullup (2k2), max 12V in
Aux Out
30V, 3A max
External Power Out (power limited)
12V, 500mA max
Operating Temperature
0 to +49°C (32 to 120°F)
Humidity
5-85±5% at 30±2°C (86±4°F)
Weight
185 g
Dimensions
197 x 60 x 28 mm
Janus C4 I/O Blade
Installation Guide
janus
C4
JC4-ADV-BL-IO16
Electromagnetic Compatibility
Following the provisions of EMC Directive 2014/30/EU,
this product complies with the following standards:
EN 55022:2010 Class B
EN50130-4:2011 inc A1:2014
IEC 62599-2:2010
WEEE
Please refer to www.grosvenortechnology.com/
legal-info/ for disposal instructions under EU Directive
2012/19/EU.
Part number:
Question and Answer IconNeed help?

Do you have a question about the Janus C4 I/O Blade and is the answer not in the manual?

Summary

Janus C4 I;O Blade Specification

Electromagnetic Compatibility

WEEE Disposal Information

Connections Overview

Auxiliary Input Connections

Details supervised inputs and optional line resistors for fault detection.

Auxiliary Output Connections

Information on volt-free contacts for low voltage systems up to 30V/3A.

Power Supply

Explanation of the 12Vdc power supply for connecting associated devices.

Power Consumption

Blade LED Indicators

Status LED Codes

LED indicators for board monitoring, device configuration, and electrical issues.

Blade Activity Reporting

LED indications for firmware download, board operation, and state changes.

Overview

The Janus C4 I/O Blade is a plug-in unit designed to expand the capabilities of Janus C4 Single-Blade or Multi-Blade Controllers. It facilitates the connection of up to 8 supervised inputs and 8 volt-free relay outputs, with clearly labeled connectors to simplify installation.

Function Description:

The I/O Blade serves as an interface for various external devices, allowing for the integration of security and access control systems. It supports both supervised and unsupervised input connections, enabling fault detection for enhanced security. The volt-free relay outputs can be used to control low-voltage systems such as barriers or turnstiles, provided the voltage and current limits are respected. The device draws 12V power from the connected Janus C4 Controller.

Important Technical Specifications:

Overview:

  • Model: Janus C4 IO16 Blade
  • Aux Inputs: 5V pullup (2k2), max 12V in. These inputs are supervised and can optionally use line resistors for fault detection. They support both contacts-only (no fault detection) and supervised (short/open circuit detect) configurations. The Aux input is pulled to 5V by the Blade using an internal circuit.
  • Aux Out: 30V, 3A max. These are volt-free contacts (Normally Closed, Common, Normally Open) suitable for controlling low-voltage systems.
  • External Power Out (power limited): 12V, 500mA max. This output provides 12Vdc power for connecting associated devices.

Environmental:

  • Operating Temperature: 0 to +49°C (32 to 120°F)
  • Humidity: 5-85±5% at 30±2°C (86±4°F)

Physical:

  • Weight: 185 g
  • Dimensions: 197 x 60 x 28 mm

Power Consumption (from Controller):

  • I/O Blade Quiescent Current: 83 mA max @12V (1.0W)
  • I/O Blade Maximum Current (all AUX Output Inputs grounded, all AUX Output relays active): 333 mA @12V (4.0W)
  • External 12V output (if used): up to 500 mA max @12V (6.0W)

Usage Features:

Input Connections:

  • Inputs 1-8: Each input has terminals for In+ and GND-.
  • Contacts Only (no fault detection): Simple switch connection between In+ and GND.
  • Supervised (short/open circuit detect): Utilizes 1K resistors in series with the input switch for short circuit detection and a 1K resistor in parallel with a 2K2 resistor for tamper switch detection, connected between In+ and GND.

Output Connections:

  • Outputs 1-8: Each output provides Out NC (Normally Closed), Com (Common), and Out NO (Normally Open) terminals.
  • Volt-free contacts: These relays are suitable for controlling low-voltage systems, ensuring the voltage across contacts does not exceed 30V and current does not exceed 3A.

Power Supply:

  • OUT terminals: OV and +12V for connecting associated devices, providing a 12Vdc power supply.

Maintenance Features:

Blade LED Indicators:

The main Blade LED Indicator provides crucial information about the device's activity and state.

  • Status LED:
    • Continuously red: Indicates the Blade is not communicating with the controller.
    • Flashing codes (every 15 seconds) for Blade State:
      • 5 blue flashes: Board is not being monitored; probably no download to controller from Janus C4.
      • 5 red flashes: Wrong device type configured (e.g., Door defined on an IO Blade).
      • 3 red flashes: Out of range device configured.
      • 5 green flashes: No devices configured for board.
      • 5 yellow flashes: Reports electrical issues such as current tripped, over voltage, under voltage, over current, or under current.
  • Blade Activity (reported by LED):
    • Yellow flicker (lasts about 30 seconds): Firmware download in progress.
    • Green blink (every 5 seconds): Board running OK.
    • Blue blink: Read activity.
    • Yellow blink: Input state change.
    • Red blink: Output state change.

Electromagnetic Compatibility (EMC):

The product complies with the following standards under EMC Directive 2014/30/EU:

  • EN 55022:2010 Class B
  • EN50130-4:2011 inc A1:2014
  • IEC 62599-2:2010

WEEE Compliance:

Disposal instructions are available on the Grosvenor Technology website (www.grosvenortechnology.com/legal-info/) under EU Directive 2012/19/EU.

Contact Information:

  • Email: info@grosvenortechnology.com
  • Telephone: +44 (0)1279 838000
  • Web: www.grosvenortechnology.com

Janus C4 I/O Blade Specifications

General IconGeneral
BrandJanus
ModelC4 I/O Blade
CategoryI/O Systems
LanguageEnglish