  • A
    Angela ScottAug 4, 2025
    Why can't I ignite the arc on my Jasic Cutter?
    • J
      Joseph JohnsonAug 4, 2025
      The Jasic Cutter arc may fail to ignite due to several reasons. First, check if the input voltage is too low. Second, verify that the air pressure isn't overly high or low.
  • V
    valerieavilaAug 12, 2025
    What to do if there is no HF discharge rustling and the red LED inside the Jasic Cutter is off?
    • B
      Brianna WhiteAug 12, 2025
      If your Jasic Cutter's solenoid valve works but there's no HF discharge and the red LED is off, the arc ignition part may be failing. This could be due to: * Electrode sticking inside the discharge nozzle, or the interelectrode distance being too long. * A short circuit or bad contact in the primary coil of the arc ignition transformer. * Leakage of the HF capacitor 102/10KV. * Damage to the relay.
  • A
    Alex HoodAug 19, 2025
    How to fix a Jasic Cutter when the fan doesn't work and the control button is not functioning?
    • S
      smithdanielAug 19, 2025
      If the power indicator illuminates but the fan doesn't work and the control button is unresponsive on your Jasic Cutter, it may be due to overvoltage protection. Shut down the machine and restart it after a few minutes.
  • J
    James GibbsAug 27, 2025
    What to do if there is no HF discharge rustling and the red LED inside the Jasic Cutter is on?
    • S
      Shannon EverettAug 27, 2025
      If the solenoid valve functions, but there is no HF discharge and the red LED is on, it could be due to: 1) Damaged MOSFET (or IGBT) on the top PCB (damaged drive module). 2) A damaged step-up transformer on the bottom PCB. 3) A damaged control module.

Summary

Safety

Precautions for Installation

Steps and warnings for safely installing the cutting machine.

1. General Description

1.2 Technical Parameters

Detailed technical specifications for each model.

2. Installation and Connection

2.1 Installation Requirements

Guidelines for proper input and output cable connections.

3. Operation

3.4 Operation Method

Step-by-step guide on how to operate the cutting machine.

3.6 Cutting Parameters Table

Tables providing recommended cutting speeds for different materials and thicknesses.

5. Troubleshooting

Jasic CUT40 (L131) Specifications

General IconGeneral
Duty Cycle60%
Max Cutting Thickness12mm
Air Pressure0.4-0.6 MPa
Efficiency85%
Insulation ClassF
Protection ClassIP21S
Input Voltage220V
Output Current Range20-40A
Rated Output Voltage96V