89
DC FUSE PANEL LAYOUT
Below is a typical wiring layout. Your individual trailer may be different.
1 12.5 reset Bed slideout moto
r
2 15 amp Bath/lavator
y
area li
g
hts, bath fan
3 15 amp Sink li
g
ht, kitchen OHC li
g
hts
4 15 amp Power awnin
g
5 15 amp Bed area li
g
hts, bed radio, 2nd air thermostat
6 15 amp TV outlet, exterior radio, LP detector, OHC li
g
hts
7 15 amp Livin
g
area, porch li
g
ht
8 15 amp Trunk li
g
hts, hitch li
g
ht, rear ceilin
g
li
g
hts
9 15 amp Main slideout li
g
hts
10 15 amp Securit
y
li
g
hts, front roof vent, vanit
y
li
g
hts
11 20 amp Furnace
12 20 amp reset Main, kitchen, entertainment slideout moto
r
13 15 amp Refri
g
erator, rear roof vent
14 15 amp Monitor panel, water pump switch
15 vacant Reserved for option
16 vacant Reserved for option
(
A
)
80 amp Batter
y
(
+
)
to converter and fuse panel
(B) 80 amp Battery (-) to converter and fuse panel
12-volt DC Layout
CIRCUIT BREAKERS
The following table provides generic circuit breaker alignment information. Your RV may not be
exactly the same as shown depending on model, floor plan and options.
Main 50 am
p
Main breaker le
g
#1
Main 50 amp Main breaker le
g
#2
A 15 amp Microwave
B 20 amp Air conditioner #1
(
central
)
C15 am
p
GFCI circuit
(
kitchen/bathroom/exterior outlets
)
D20 am
p
Air conditioner #2
(
front
)
E 15 amp Utilit
y
Circuit #1
(
misc. outlets & ceilin
g
fan
)
F 15 amp Water heate
r
G 15 amp Utilit
y
circuit #2
(
refri
g
erator & misc. outlets
)
H20 am
p
Power converter
(
sin
g
le 80 am
p)
I15 am
p
Fire
p
lace
J 15 amp Central vacuum
K 15 amp Washer and dr
y
er combination unit
L Vacant (reserved for dryer)
120-volt AC layout
PROPANE CONSUMPTION CHART
The following chart provides an average propane consumption information.
Appliance
Average BTU
Consumption/Hr. Kilojoules/Hr.
Water Heater 8800 – 10,000 9280 – 10,550
Refrigerator 1200 – 1500 1270 – 1580
Furnace 20,000 – 40,000 21,100 – 42,200
Range w/Oven 7100 7490
Range, Rear Burner 6500 6860
Range, Front Burner 9000 9490
Outside Grill 10,000 10,550
Outside Stove 13,000 13,730