95
1. Make sure the water tank drain, and hot & cold water lines (faucets) are closed.
2. Remove the fresh water connection inlet plug and connect the short hose on the utility
center to the fresh water connection inlet. Connect the long hose on the reel to a pres-
surized fresh water source.
1. Move the “city water / fresh tank ll valve” to the FILL TANK position.
2. Move the “Aqua-Hot water heater bypass valves” to the NORMAL position (supply
valves to the water heater ON, center valve OFF).
3. Make sure the siphon valve (clear hose behind the utility pan-
el) is pointing away from the clear hose.
4. Turn ON the water at the water source.
5. Open the cold water supply faucets to bleed the air from the
water lines. When the water lines are nearly full, you may
experience some “air pockets”. Allow them to escape before
closing the cold water supply faucets.
1. Shut OFF the water at the water source.
2. Move the “city water / fresh tank ll valve” back to the vertical CITY WATER position.
3. Disconnect the hose (on the reel) and reinstall the “fresh water connection inlet” plug.
When you do not have access to a pressurized water source, you can ll the water tank from
a container of water by using the direct ll method.
The fresh water tank can be directly lled with unltered water.
Connect a non-toxic hose to a pressurized water source. Un-
screw and remove the black cap, and insert the non-toxic hose
into the direct ll inlet on the tank. Turn on the water and ll
the tank. Water can also be dumped directly into the tank using
a water container and funnel using this same inlet. The tank in-
cludes a window to monitor water level.
The water tank is located in a compartment on the passenger of
the motor home.
Depending on your model, the fresh water hose may connect
directly to the fresh water inlet at the utility center.
Install the “fresh water connection inlet” plug whenever the “fresh
water connection inlet” is not being used.