111


1. Connect the fresh water hose to the city water inlet.
2. Set the color coded valves to the CITY WATER setting:
(A) White handle pointing down
(B) Blue handle pointing left
(C) Green handle pointing left
(D) Red handle pointing right
3. Connect other end of the hose to the pressurized fresh water source.
4. Turn ON the pressurized water source.
5. Water should now be available to all xtures.
 Turn o water at the pressurized source rst, disconnect hose from the
water source, (to release pressure o the system) then disconnect the hose at the city water
connection on utility center last.

1. Connect a garden hose to the city water inlet (do not use your fresh water hose to win-
terize the water lines).
2. Set the color coded valves to the WINTERIZE setting:
(A) White handle pointing right
(B) Blue handle pointing left
(C) Green handle pointing left
(D) Red handle pointing right
The water heater is bypassed automatically on this setting.
3. Insert the other end of the hose in a container holding RV antifreeze.
4. Turn the pump switch ON.
5. Antifreeze should begin owing into the plumbing lines and xtures (the pump will
run when a faucet or the toilet is in use). To aid in siphoning place the container on a
surface approximately (2) feet o the ground.
6. Open one plumbing xture, keeping it open until antifreeze appears then close it. Re-
peat for each plumbing xture (including the outside shower hot & cold lines).
7. Turn the pump OFF when all xtures have been winterized.
8. Disconnect the hose from the city water connection inlet (it is normal for some anti-
freeze to exit the inlet hose as it is being disconnected).
9. Leave the valves set on WINTERIZE setting.


When your RV is new.
At the beginning and end of each season.
When the water system becomes contaminated or every three months of use.
 For  winterizing instructions refer to the
Winterizing the Plumbing System section.

