EasyManua.ls Logo

Jayco Precept - Section 13: Exterior (Continued); Ladder Capacity and Sealant Inspection

Jayco Precept
165 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
117

7. Turn the (color) valve handles to the POWERFILL position.
8. Low point drains should be open to remove water from the lines.
9. Open all faucets in the RV. If there is an outside shower, attach the shower hose to the
shower, and open shower faucets.
10. Drain plug should be removed from tank (storage) water heater.
11. Run the water pump until pump is dry (approximately 15 to 20 seconds). Do not oper-
ate pump longer than that without water, it can damage the pump.
12. After water is drained from the lines, turn the Red, Blue, Green and White valves so
they are at 45° 
13. Attach a blowout plug to the City Water Inlet on the utility center panel 
14. Attach the air hose to the blowout plug. Set the compressor to . Set the four
color valves to 45° angle 

15. Blow air into the utility center. Water lines should be clear in 5 to 10
minutes.
16. Turn o air supply, remove air hose and blowout plug.
17. Close low point drains, replace the water heater drain plug. (Tankless water heater
should now be purged of water)
18. Set the colored valves to the WINTERIZE positions.
          

19. Pour one cup of RV antifreeze in all drain P-traps (sinks and bathtub).

1. Connect the blowout plug to the Black Tank Flush inlet at the utility center panel.
2. Colored valves have no eect on the black tank ush inlet.
3. Connect the air hose to the blowout plug. Set the compressor to .
4. Make sure the black tank has been emptied. Open the black tank drain gate valve.
5. Blow air into the ush inlet for 30 to 60 seconds.
6. Disconnect the air hose, compressor and blowout plug.
7. Close the black tank drain gate valve (typically under the RV).
 Appliances (refrigerator, dishwasher or clothes washer)
must be winterized. Refer to the appliance owner’s manual for
possible additional information or contact your Dealer or Customer
Service for assistance.
 Filters should be replaced at the beginning of the camping
season or if they have been exposed to contaminated water or
antifreeze..

