7
CROSS SENSITIVITY
TO AUTOMOTIVE CHEMICALS
Some automotive solvents and chemicals have similar hydrocarbon properties as
R-134a and may elicit a positive response (<30 seconds) from the PROWLER. Before
leak checking, clean up any of the following chemicals that elicit a positive response:
• Rain-X windshield Wash Fluid
• Ford Spot Remover (wet)
• Ford Rust Inhibitor
• Ford Gasket Adhesive (wet)
• Loctite Natural Blue degreaser (diluted)
• Ford Brake Parts Cleaner
• Ford Silicone Rubber (uncured)
• Motorcraft Antifreeze heated to 160° F
(PARTIAL RESPONSE)
• Gunk liquid wrench
• Ford Pumice lotion (with solvent)
• Ford Motorcraft brake fluid
• Ford Carburetor Cleaner
PROWLER SPECIFICATIONS
MODEL #: LD-5000
NAME: PROWLER Leak Detector, Refrigerant Gas
SENSITIVITY:
(oz/yr)
R-22 (0.025), R-134a (0.05), R-1234yf (0.0125), R-410A (0.05), R-404A
(0.05), R-407A (0.05), R-427A (0.05)
SENSOR LIFE: > 10 years (normal use)
RESPONSE TIME: Instantaneous
POWER SUPPLY: 4 AA Alkaline batteries
BATTERY LIFE: 4-6 hours continuous
WARM UP TIME: < 20 seconds
PROBE LENGTH: 17 inches
LCD DISPLAY: Sensitivity, Battery Life, Leak Level Indication
WEIGHT: 1 lb 3.4 oz
WARRANTY:
2 years includes sensor
EN 14624 TEST SPECIFICATIONS
MIN/MAX SENSITIVITY
THRESHOLD (FIXED): 1 gm/yr minimum, > 50 gr/yr maximum
MIN/MAX SENSITIVITY
THRESHOLD (MOVING): 3 gm/yr minimum, > 50 gm/yr maximum
MIN DETECTION TIME: Approximately 1 second
CLEARING TIME:
Approximately 9 seconds after exposure to
> 50 gm/yr
MIN THRESHOLD AFTER
MAX EXPOSURE: 1 gr/yr
SENSITIVITY THRESHOLD IN
POLLUTED ATMOSPHERE: 1 gm/yr
CALIBRATION FREQUENCY: 1/yr check with calibrated leak standard