Do you have a question about the JEAN LUTZ TARALOG and is the answer not in the manual?
Explains TARALOG unit mounting and cable connections in junction boxes.
Details the B2FJ1 junction box and the TARALOG electrical power supply connection.
Describes the umbilical cable and B1FB1 box for rotation sensors.
Details the mounting and operation of the VR28 rotation sensor.
Details the mounting and operation of the F89 depth sensor.
Description and application of C16 400 pressure sensors.
Step-by-step guide for mounting the IA1620 inclinometer to the mast.
Details on installing and using the optional DC7 cable winder.
Instructions for installing the concrete pressure separator.
Setup for R801E (pump side) and R801 R (machinery side) radios.
Setup for R511P (pump side) and R511M (rig side) radios.
Setup for R411P (pump side) and R411M (rig side) radios.
Overview of the four primary operating modes of the TARALOG system.
Explanation of the mode for initiating a new pile construction.
Description of the mode for data acquisition during drilling and concreting.
Explanation of the mode for system settings and configuration.
Description of the TARALOG's front panel controls and keyboard.
Explanation of how hidden icons are accessed and used on the interface.
Overview of the idle mode, its screen layout, and icon functions.
Step-by-step process for using the 'Start New Pile' mode.
Information on MEMOBLOC capacity, usage, and data viewing.
Details on drilling phase and PAUSE/MEASURE positions within the mode.
Description of the operations during the concreting phase.
Explanation of default and extended volume management methods.
How to configure and perform manual data transfer via email.
General description of radio system capabilities for concrete flow measurement.
How to view stored data and clear MEMOBLOC contents.
Steps for configuring and executing automatic mast positioning.
How to navigate and use the programming mode for settings.
Settings for different sensors: zero, full scales, etc.
Parameters for numerical data recording on the MEMOBLOC.
Configuration of the TARALOG's internal clock.
Settings for display information and screen formatting.
Choice and adjustment of lifting type controls.
Depth coefficient and displacement direction settings.
Parameters for concrete flow and volume measurements.
Enter number of pulses per revolution for rotation sensor.
Adjust sensor zero for concrete pressure.
Adjust sensor zero for torque.
Choose torque unit and conversion factors.
Configure speed input coding based on machine signals.
Configure speed input using binary code from the machine.
Configure speed input using 240351 code from the machine.
Configure torque calculation based on hydraulic pressure.
Adjust the zero offset for the X inclination sensor.
Adjust the zero offset for the Y inclination sensor.
Adjust the zero offset for the traction pressure sensor.
Adjust the zero offset for the thrust pressure sensor.
Enable/disable data recording and set acquisition interval.
Procedure for reading MEMOBLOC data via PC.
Set the internal time and date of the TARALOG.
Set maximum depth and profile display parameters.
Configure bargraph for overconsumption with tolerances.
Enable automatic zeroing of concrete pressure.
Define auger tube dimensions for volume calculation.
Option to record slump and delivery note data.
Input the machine's identification number.
Add text comments to recorded data.
Choose between continuous flight auger or Kelly modes.
Configure parameters for sending data via email.
Select print-out modes for the TP110 printer.
Set concrete layer parameters and adjust lifting valve logic.
Configure automatic and manual mast positioning.
Steps for loading new software onto the TARALOG unit.
How to access and use hidden menus for advanced settings.
General plan, dimensions, and fastening of the TARALOG unit.
Technical specifications for the B1FB1 connection box.
Technical specifications for the B2FJ1 junction box.
Technical specifications for the umbilical cable.
Technical specifications for the DC7 cable winder.
Technical specifications for the F89 depth sensor.
Technical specifications for the IA1620 inclinometer.
Technical specifications for the C1650D pressure sensor.
Technical specifications for the SP400 separator.
Technical specifications for the VR28 rotation sensor.
Technical specifications for the C16 400 torque sensor.
Technical specifications for the TP110nx printer.
Technical specifications for the MEMOLEC SCU reader.
Technical specifications for the MEMOTEL module.
Technical specifications for R511 radios.
Technical specifications for R411 radios.
| Brand | JEAN LUTZ |
|---|---|
| Model | TARALOG |
| Category | Control Systems |
| Language | English |