EasyManua.ls Logo

Jecod DCP-3000 User Manual

Jecod DCP-3000
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DC Pump
OWNER’S MANUAL
DCP-3000
DCP-4000
DCP-5000
DCP-6500, DCP-8000,
DCP-10000
DCP-15000
DCP-18000
DCP-20000
Introduction
The DCP pumps are carefully inspected and tested to ensure both safety and operating
performance. However, failure to follow the instructions and warnings in this manual
may result in pump’s damage and/or serious injury. Be sure to read and save this
manual for future reference.
Pump Features
High performance with innovative motor, and energy saving up to 65%, super
quiet operation.
IC electronic detection, automatic power-off protection upon no water.
No-copper element.
Suitable for both marine and fresh water, Rust free.
With anti-resistant ceramic shaft, Longer operation file.
Controller Features
Adjustable the flow rate and head max.
“Feed” Model, pause, timing, delay, restart function
Memory function, ensure that the pump rework upon keeping the same parameter
Operating instructions
1. The pump must be connected with the controller and the 24V or 36V adaptor
correctly before work
2. Lock / unlock function: press the "+" or "-" button for three seconds until the LED
light flash for two times, the controller locked; Similarly, press the "+" or "-" button for
three seconds again, LED indicator light flashes for two times, the controller unlocked
3. "FEED" function: when the pump is working, press "FEED" button, pump stops
working, the "10min" indicator lights up, the pump reworks automatically at previous
level after 10 minutes. Or you can press the “FEED” button to make the pump rework.
Control and Panel Function
First, LED display and controller key Instructions
As indicated in able diagram LED indicates power work/stop and fault code, the panel
are touched control
Seconds, operating instructions
After connected with pump, the control is set per last operation, panel is shown on LED,
touch work /stop button, the pump will stop working, and OFF indicate in LED. Touch
work/stop button again, the pump resume working, Led shows normal locking panel.
PXXX is shown in LED, P is short for power, there are 71 settings for working panel,
when touch slow/fast button, LED will show the instant working condition, you can set
different power per your need. When sets “watts “ button the Led display the “watts”
button were “FXXbutton from 30 to 100SP is Speed shortening. More than 1 S no
setting “watts” button, the led auto change its display “watts” button.
Three, the key Lock Function
Turn on the power, press the "+" or "-" button for three seconds until the LED light
flash for two times, the controller locked; Similarly, press the "+" or "-" button for three
seconds again, LED indicator light flashes for two times, the controller unlocked
Four, The Led protected mode
Turn on the power , more than 25 seconds no touch control button, the LED to micro
bright, the controller enter the screen saver mode; the led return to normal When press
any button.
Question and Answer IconNeed help?

Do you have a question about the Jecod DCP-3000 and is the answer not in the manual?

Jecod DCP-3000 Specifications

General IconGeneral
BrandJecod
ModelDCP-3000
CategoryWater Pump
LanguageEnglish

Summary

Introduction

Controller Features

Operating Instructions

The pump must be connected with the controller and the 24V or 36V adaptor correctly before work.

Control and Panel Function

LED Display and Key Instructions

LED indicates power work/stop and fault code, the panel are touched control.

Panel Operating Instructions

After connected with pump, the control is set per last operation, panel is shown on LED, touch work/stop button, the pump will stop working.

Key Lock Function

Press the '+' or '-' button for three seconds until the LED light flash for two times, the controller locked.

LED Protected Mode

After 25 seconds no touch control button, the LED to micro bright, entering screen saver mode.

Date and Fault Code Information

Date Memory Function

Memory function, ensures that the pump rework upon keeping the same parameter.

Fault Code and Description

The fault code abnormal and flashing when the controller abnormal work, the code explanation is as below.

Safety Warnings and Precautions

General Warnings

Do not connect to any other power supply over the rated voltage; do not put the pump in flammable liquid.

Usage Cautions

Always disconnect the pump from power supply before cleaning, maintenance and handling. Do not let the pump work dry.

Operation

Submersible Pump Usage

Important Note

Do not let the pump run dry - this could cause damage to the motor.

Submersible Installation

Submerse the pumps completely in your pond so as to make the pump body fill with water.

Non-Submersible Pump Usage

Non-Submersible Installation

Position the pump lower than the water surface on the side of the pond so that the water can be drained to the pump.

Never Run Dry

Never let the pump run dry.

Maintenance

Cleaning Procedure

To clean the pump, remove the back cover, sealing cover and the impeller. Use a small brush or stream of water.

Troubleshooting

If the pump not work, check the circuit, pump outlet and tube, and the inlet.

Disposal Information