22
Troubleshooting
ISSUE: Battery voltage is too high (Error 105).
SOLUTION: Change battery with less voltage than 17.0 volts.
ISSUE: High current ow the mosfet (Error 106).
SOLUTION: Check if motor or gears is damaged or jammed. Check wires to motor for short
circuits or exposed connections. Could be problem of unballanced gun upgrade.
ISSUE: Battery voltage is too low (Error 107).
SOLUTION: Change or charge battery to have more voltage than 5.5 volts.
ISSUE: High temperature on the processor (Error 108).
SOLUTION: check for short circuits on leviathan through the gearbox or damaged parts.
ISSUE: Motor is disconnected (Error 109).
SOLUTION: Check motor and contacts for it, if they aren‘t damaged or disconnected.
ISSUE: Nonfunctional application (Error 200).
SOLUTION: Program error in the Leviathan. Make update rmware to the newest version.
ISSUE: Gun suddenly stopped ring.
SOLUTION: Protection could be activated - check error log. Check battery charge. Check
motor contacts and motor functionality. Check if the safety fuse hasn’t been blown.
ISSUE: The Leviathan is not visible in the device list in the application.
SOLUTION: Click to refresh button in the app. Check if battery is charged and connected
into the Leviathan. Enable wireless and location in your phone. Restart mobile app.
ISSUE: You programmed the Leviathan, now it doesn‘t do what you wanted.
SOLUTION: Best way is to do FACTORY RESET and start again.
ISSUE: The gun does something strange or nothing.
SOLUTION: STOP! Release trigger, disconnect battery and search for the problem before-
something will be irreversibly damaged! Contact us at email support@jetron.cz.