Startup codes
After connecting battery Leviathan - V2 does a power up self check, which lasts a 1s.
It results the motor vibration or error beeps with the error log record:
1 short vibration - All systems are OK. This vibration is about half second long.
1 short beep - Trigger is pressed during battery connection (102)
2 short beeps - High current ow the mosfet (106)
3 short beeps - High temperature on the mosfet (104)
1 long beep - Battery voltage is less than 5.5 volts (107)
2 long beeps - Battery voltage is more than 17.0 volts (105)
3 long beeps - High processor temperature (108)
short-long-short beep - Motor is disconnected (109)
long-short-long beep - Nonfunctional application (200)
Post ring codes
If any problem occurs during ring, it will be signaled by beeps with the error log record:
1 short beep - Micro switch for sector gear is pressed after the motor stop (100)
short-long beep - Micro switch for sector gear isn‘t pressed after the trigger pull (103)
2 short and long beep - Selector plate has moved during shooting (101)
2 short beeps - High current ow the mosfet (106)
3 short beeps - High temperature on the mosfet (104)
1 long beep - Battery voltage is less than 5.5 volts (107)
3 long beeps - High processor temperature (108)
1 vibration after shot - Battery voltage is low. If the battery drops much further, the gun
will vibrate instead ring. Now it is a good time to change your battery for new one.
1 vibration instead of re - Battery is discharged. The gun vibrates on every trigger pull.
change your battery for new one. WARNING: battery still slowly discharging.
1 vibration after some time - When is delay between shot activated, it vibrates after the
delay time ends. It is for notication the gun is ready for shooting.