14
Troubleshooting
ISSUE: Battery voltage is too high (Error 105).
SOLUTION: Change battery with less voltage than 17.0 volts.
ISSUE: High current ow the mosfet (Error 106).
SOLUTION: Check if motor or gears is damaged or jammed. Also check wires to motor for
short circuits or exposed connections.
ISSUE: Battery voltage is too low (Error 107).
SOLUTION: Change or charge battery to have more voltage than 5.5 volts.
ISSUE: High temperature on the processor (Error 108).
SOLUTION: check for short circuits on the leviathan-V2 through the gearbox.
ISSUE: Motor is disconnected (Error 109).
SOLUTION: Check contacts for the motor, if they aren‘t damaged or disconnected.
ISSUE: Nonfunctional application (Error 200).
SOLUTION: Program error in the Leviathan-V2. Update rmware to the newest version.
ISSUE: Gun suddenly stopped ring.
SOLUTION: Protection could be activated - check error log. Check battery charge. Check
motor contacts and motor functionality. Check if the safety fuse hasn’t been blown.
ISSUE: Leviathan - V2 is not visible in the device list in the application.
SOLUTION: Click t orefresh button in the app. Check if it is charged and connected battery
into the Leviathan-V2. Enable Bluetooth and GPS in your phone. Restart mobile app.
ISSUE: You programmed Leviathan - V2, now it doesn‘t do what you wanted.
SOLUTION: Best way is to do FACTORY RESET and start again.
ISSUE: The gun does something strange or nothing.
SOLUTION: STOP! Release trigger, disconnect battery and search for the problem before
something will be irreversibly damaged! Contact us at email support@jetron.cz.