JingYan TLL90S - Modbus Register Control; Registers for Writing Data; Output Port Configuration; Selecting Output Communication Port

JingYan TLL90S
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2022 Aug 15
0x006B
Low 16 bit
complement 0001= 000.1 Degree
0x006C
High 16 bit
Sensor’s temperature 00001=000.01
degree Celsius
0x006D
Low 16 bit
Register to Write
Address
Purpose (16 bit data)
0x12C
Measuring
Mode
0
Tilt angle reading mode
1
Gyro measuring mode
0x12D
Measuring
Format
0
Degree
1
mm/M
2
Gradient (Slope)
ADDRESS: 1-255 is TLL90S Modbus device address, selection by “ZERO and “ HOLD
button and then press “SET” to confirm
BUAD RATE: 9600, 19200, 38400, 56000, 57600, 115200bps selection by “Up” and
“ Down” button and then press “Set” to confirm. Need power reset to active new buadrate.
Choose the output port
1. Press and hold “Angle/Set” key and enter MENU mode
2. Select “COMMUNICATION” by “ZERO” and “HOLD” key, press “SET” key to
enter Data communication
3. Scroll “USB” or “RS485” by “Zero” and “HOLD” key